Evidence map›Paper›PMID 32647145›Full record

ArticleScientific reports2020

BEaTS-α an open access 3D printed device for in vitro electromechanical stimulation of human induced pluripotent stem cells.

David Cortes, Christopher D McTiernan, Marc Ruel, Walfre Franco, Cencen Chu, Wenbin Liang, Erik J Suuronen, Emilio I Alarcon

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David Cortes *Biomedical Mechanical Engineering, University of Ottawa, Ottawa, ON, K1N6N5, Canada.
Christopher D McTiernan *Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, ON, K1Y4W7, Canada.
Marc RuelDivision of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, ON, K1Y4W7, Canada.
Walfre FrancoWellman Center for Photomedicine, Department of Dermatology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA.ORCID http://orcid.org/0000-0003-0905-4083
Cencen ChuCardiac Electrophysiology Laboratory, University of Ottawa Heart Institute, Ottawa, ON, K1Y4W7, Canada.
Wenbin LiangCardiac Electrophysiology Laboratory, University of Ottawa Heart Institute, Ottawa, ON, K1Y4W7, Canada.
Erik J SuuronenDivision of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, ON, K1Y4W7, Canada.
Emilio I AlarconDivision of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, ON, K1Y4W7, Canada. ealarcon@ottawaheart.ca.ORCID http://orcid.org/0000-0001-5100-6179

Funding

CIHR
6 · The paper itself

Abstract

3D printing was used to develop an open access device capable of simultaneous electrical and mechanical stimulation of human induced pluripotent stem cells in 6-well plates. The device was designed using Computer-Aided Design (CAD) and 3D printed with autoclavable, FDA-approved materials. The compact design of the device and materials selection allows for its use inside cell incubators working at high humidity without the risk of overheating or corrosion. Mechanical stimulation of cells was carried out through the cyclic deflection of flexible, translucent silicone membranes by means of a vacuum-controlled, open-access device. A rhythmic stimulation cycle was programmed to create a more physiologically relevant in vitro model. This mechanical stimulation was coupled and synchronized with in situ electrical stimuli. We assessed the capabilities of our device to support cardiac myocytes derived from human induced pluripotent stem cells, confirming that cells cultured under electromechanical stimulation presented a defined/mature cardiomyocyte phenotype. This 3D printed device provides a unique high-throughput in vitro system that combines both mechanical and electrical stimulation, and as such, we foresee it finding applications in the study of any electrically responsive tissue such as muscles and nerves.

Indexed as

Computer-Aided DesignPrinting, Three-DimensionalElasticityElectric StimulationHumansInduced Pluripotent Stem CellsMyocytes, CardiacPhenotypeSiliconesSoftwareStress, MechanicalTranslational Research, BiomedicalSilicones

Identifiers

PMID32647145
PMCPMC7347879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.