Evidence map›Paper›PMID 32646450›Full record

ArticleJournal of orthopaedic surgery and research2020

Single versus dual orthogonal plating for comminuted midshaft clavicle fractures: a biomechanics study.

Glenn N Boyce, Andrew J Philpott, David C Ackland, Eugene T Ek

Abstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Usefulness of double plate fixation after failed ORIF for clavicle shaft fracture.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Article
  5. Anterior and superior plate positions in diaphyseal clavicle fractures produce similar patient outcomes.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Glenn N BoyceMelbourne Orthopaedic Group, 33 The Avenue, Windsor, Melbourne, VIC, 3181, Australia.
Andrew J PhilpottMelbourne Orthopaedic Group, 33 The Avenue, Windsor, Melbourne, VIC, 3181, Australia.
David C AcklandDepartment of Biomedical Engineering, University of Melbourne, Melbourne, VIC, Australia.
Eugene T EkMelbourne Orthopaedic Group, 33 The Avenue, Windsor, Melbourne, VIC, 3181, Australia. eugene.ek@mog.com.au.ORCID http://orcid.org/0000-0003-3779-3545

Funding

Melbourne Orthopaedic Group Research Foundation -
6 · The paper itself

Abstract

backgroundDual orthogonal plating of clavicle fractures may provide greater stiffness and strength than unilateral plate constructs and allow the use of lower-profile plates. We aim to biomechanically compare three clavicle plating constructs in a comminuted clavicle fracture model.

methodFifteen clavicle sawbones were osteotomised, simulating a comminuted midshaft fracture and allocated to either: group 1, single superior plate (3.5 mm superior plate); group 2, combination plating (3.5 mm superior plate, 2.8 mm anterior plate) and group 3, dual mini-plates (two 2.8-mm orthogonal mini-plates). Specimens were biomechanically tested under torsion and cantilever bending. Construct stiffness (Nm/degree) and load to failure (Nm) were measured.

resultsGroup 2 had higher torsional (0.70 vs. 0.60 Nm/deg, p = 0.017) and cantilever bending stiffness (0.61 vs. 0.51 Nm/deg, p = 0.025) than group 1. Group 3 had lower cantilever bending stiffness (0.39 vs. 0.51 Nm/deg, p < 0.004) and load to failure (40.87 vs. 54.84 Nm, p < 0.01) than group 1. All dual plate constructs that catastrophically failed did so from fracture at the lateral ends of the plates. Single plate constructs failed due to plate bending.

conclusionDual orthogonal fixation with mini-plates demonstrated lower stiffness and strength than traditional superior plating. The addition of an anterior mini-plate to a traditional superior plating improved construct stiffness and may have a role in patients seeking early return to activity. LEVEL OF EVIDENCE: Basic science biomechanical study.

Indexed as

Bone PlatesBiomechanical PhenomenaClavicleCompressive StrengthFracture Fixation, InternalFractures, ComminutedHumansModels, AnatomicBiomechanicalClavicleComminutedFractureInternal fixationOrthogonalSegmental

Identifiers

PMID32646450
PMCPMC7346347

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked