Bioanalytical Performance of a New Particle-Enhanced Method for Measuring Procalcitonin.

Anne Marie Dupuy, Anne Sophie Bargnoux, Romaric Larcher, Antoine Merindol, Thomas Masetto, Stéphanie Badiou, Jean Paul Cristol

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Anne Marie DupuyLaboratoire de Biochimie et Hormonologie, CHU Montpellier, Université Montpellier 1, F-34295 CEDEX 5 Montpellier, France.ORCID 0000-0001-6538-3944
Anne Sophie BargnouxLaboratoire de Biochimie et Hormonologie, CHU Montpellier, Université Montpellier 1, F-34295 CEDEX 5 Montpellier, France.
Romaric LarcherLaboratoire de Biochimie et Hormonologie, PhyMedExp, Université de Montpellier, INSERM, CNRS, CHU de Montpellier, 34295 Montpellier, France.
Antoine MerindolLaboratoire de Biochimie et Hormonologie, CHU Montpellier, Université Montpellier 1, F-34295 CEDEX 5 Montpellier, France.
Thomas MasettoInstitute of Molecular Medicine I, Medical Faculty, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany.ORCID 0000-0001-9609-3405
Stéphanie BadiouLaboratoire de Biochimie et Hormonologie, CHU Montpellier, Université Montpellier 1, F-34295 CEDEX 5 Montpellier, France.
Jean Paul CristolLaboratoire de Biochimie et Hormonologie, CHU Montpellier, Université Montpellier 1, F-34295 CEDEX 5 Montpellier, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We report the analytical performances of two particle-enhanced (PETIA) methods for measuring procalcitonin (PCT), the Diazyme PCT and the new DiaSys PCT assay, and their concordance of values with BRAHMS PCT Kryptor©. The total imprecisions onto two control levels and one serum pool were for DiaSys 5.42%, 3.3% and 7.53% and for Diazyme 10.7%, 2.9% and 13.23%, respectively. The limit of blank, limit of detection and limit of quantification were under the 0.25 cut-off for the two methods. The linearity in the lower range was acceptable for both methods. No significant effect on PCT determination was observed for DiaSys' assay upon addition of interfering substances. With the Diazyme assay, significant effects were seen with rheumatoid factor (RF), lipid and hemoglobin. Correlation studies on 136 sera showed a good correlation between PCT measurements using DiaSys assay against the Kryptor system, while only a poor correlation was observed between the Diazyme assay, especially for low values. The novel PETIA PCT assay from DiaSys shows analytical performances acceptable for clinical use and the concordance with Kryptor method was fine at all clinical cut-offs. In contrast, despite comparable analytical performances, the Diazyme PETIA method exhibited a poor concordance with the Kryptor method.

Indexed as

clinical concordancecorrelationPCTprecision