ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2021
Initial experience with the novel p64MW HPC flow diverter from a cohort study in unruptured anterior circulation aneurysms under dual antiplatelet medication.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 2 syntheses or guidelines pooled it, 27 citations in OpenAlex.
- DWI-Detected Ischemic Lesions after Endovascular Treatment for Cerebral Aneurysms: An Updated Systematic Review and Meta-analysis.AJNR. American journal of neuroradiology · 2023Pooled it
- Outcomes Associated With Intracranial Aneurysm Treatments Reported as Safe, Effective, or Durable: A Systematic Review and Meta-Analysis.JAMA network open · 2023Pooled it
- Light Transmission Aggregometry Versus VerifyNow for Antiplatelet Monitoring in Flow Diversion: A Retrospective Comparative Study.Diagnostics (Basel, Switzerland) · 2026Article
- Multicenter study of the safety and effectiveness of intracranial aneurysm treatment with the p64MW-HPC flow modulation device.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- The use of FD-HPC in Ruptured and Unruptured Aneurysms, the Italian Dataset (RUAID): Preliminary results on feasibility and safety.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- The DERIVO 2 Heal Embolization Device in the Treatment of Ruptured and Unruptured Intracranial Aneurysms: a Retrospective Multicenter Study.Clinical neuroradiology · 2025Article
- Multicenter study of HPC coated p48 and p64 flow diverters for treatment of intracranial aneurysms under dual antiplatelet therapy.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Initial Experience with the New DERIVOBrain sciences · 2024Article
- Systematic Review and Meta-Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms.Stroke (Hoboken, N.J.) · 2024Article
- Coating (Coating to Optimize Aneurysm Treatment in the New Flow Diverter Generation) study. The first randomized controlled trial evaluating a coated flow diverter (p64 MW HPC): study design.Journal of neurointerventional surgery · 2023Article
- Flow Diverter Performance for the Treatment of Intracranial Aneurysms: An International Multicenter Comparative Study.Stroke (Hoboken, N.J.) · 2023Article
- Acute Distal Migration and Shortening of the Flow-Redirection Endoluminal Device: A Case Report.Journal of neuroendovascular therapy · 2023Article
- Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Article
- Risk Factors for Cerebral Aneurysm Rupture in Mongolia.Clinical neuroradiology · 2022Article
- Comprehensive review of the recent advances in devices for endovascular treatment of complex brain aneurysms.The British journal of radiology · 2022Review
- First multicenter experience using the Silk Vista flow diverter in 60 consecutive intracranial aneurysms: technical aspects.Journal of neurointerventional surgery · 2021Article
- Treatment of Intracranial Aneurysms Using the New Silk Vista Flow Diverter: Safety Outcomes at Short-Term Follow-Up.Frontiers in neurology · 2021Article
- First Experience of Three Neurovascular Centers With the p64MW-HPC, a Low-Profile Flow Diverter Designed for Proximal Cerebral Vessels With Antithrombotic Coating.Frontiers in neurology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivep64MW HPC is a new low-profile flow diverter with reduced thrombogenicity due to hydrophilic coating. The purpose of this study was to evaluate its safety and efficacy in Mongolian patients under dual antiplatelet therapy.
methodsConsecutive patients with unruptured anterior circulation aneurysms were prospectively enrolled. All patients received aspirin and clopidogrel before and six months after the procedure, followed by lifelong aspirin medication. High platelet reactivity (VerifyNow) did not trigger further action. The safety and efficacy endpoints were clinical outcome and aneurysm occlusion.
resultsIn 29 patients (26 female, median age 57 years), 46 aneurysms (neck width 3.3 mm, fundus diameter 3.7 mm, median) were treated. Dual platelet function inhibition was confirmed in eight patients (28%). The response to Clopidogrel was between 100 and 239 P2Y12 reaction units (VerifyNow) in 13 patients (45%). Non-response to at least one drug was found in 8 of 29 patients (28%). One collapsed p64MW HPC required balloon angioplasty. No other periprocedural thrombus formation occurred. Postprocedural MRI revealed lesions with diffusion restriction in 3 of 29 patients. Digital subtraction angiography after three months for 42 of 46 (91%) aneurysms showed an adequate aneurysm occlusion in 25 (60%). Distal p64MW HPC migration of 3 implants was retreated with another p64MW HPC. Follow-up digital subtraction angiography of 26 of 46 (57%) aneurysms after six months showed adequate aneurysm occlusion in 22 (85%). Significant in-stent stenosis or thrombosis, morbidity or mortality was not encountered.
conclusionp64MW HPC implantation in patients under dual antiplatelet therapy with or without dual platelet function inhibition has a low procedural complication rate. The early aneurysm occlusion rate is high.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials