Optimizing Irradiation Geometry in LED-Based Photoacoustic Imaging with 3D Printed Flexible and Modular Light Delivery System.

Maju Kuriakose, Christopher D Nguyen, Mithun Kuniyil Ajith Singh, Srivalleesha Mallidi

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Maju KuriakoseDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0003-0480-5458
Christopher D NguyenDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.
Mithun Kuniyil Ajith SinghResearch and Business Development Division, CYBERDYNE INC, 3013 AK Rotterdam, The Netherlands.ORCID 0000-0001-8670-6335
Srivalleesha MallidiDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.

Funding

NIH HHS RO1CA231606
6 · The paper itself

Abstract

Photoacoustic (PA) imaging-a technique combining the ability of optical imaging to probe functional properties of the tissue and deep structural imaging ability of ultrasound-has gained significant popularity in the past two decades for its utility in several biomedical applications. More recently, light-emitting diodes (LED) are being explored as an alternative to bulky and expensive laser systems used in PA imaging for their portability and low-cost. Due to the large beam divergence of LEDs compared to traditional laser beams, it is imperative to quantify the angular dependence of LED-based illumination and optimize its performance for imaging superficial or deep-seated lesions. A custom-built modular 3-D printed hinge system and tissue-mimicking phantoms with various absorption and scattering properties were used in this study to quantify the angular dependence of LED-based illumination. We also experimentally calculated the source divergence of the pulsed-LED arrays to be 58° ± 8°. Our results from point sources (pencil lead phantom) in non-scattering medium obey the cotangential relationship between the angle of irradiation and maximum PA intensity obtained at various imaging depths, as expected. Strong dependence on the angle of illumination at superficial depths (-5°/mm at 10 mm) was observed that becomes weaker at intermediate depths (-2.5°/mm at 20 mm) and negligible at deeper locations (-1.1°/mm at 30 mm). The results from the tissue-mimicking phantom in scattering media indicate that angles between 30-75° could be used for imaging lesions at various depths (12 mm-28 mm) where lower LED illumination angles (closer to being parallel to the imaging plane) are preferable for deep tissue imaging and superficial lesion imaging is possible with higher LED illumination angles (closer to being perpendicular to the imaging plane). Our results can serve as a priori knowledge for the future LED-based PA system designs employed for both preclinical and clinical applications.

Indexed as

Photoacoustic TechniquesPrinting, Three-DimensionalOptical ImagingPhantoms, ImagingUltrasonography3-D printed photoacoustic probe holderLEDLED divergencelight delivery optimizationphotoacoustic imagingultrasound

Identifiers

PMID32640683
PMCPMC7374354

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.