Evidence map›Paper›PMID 32632002›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2020

Active photonic wireless power transfer into live tissues.

Juho Kim, Jimin Seo, Dongwuk Jung, Taeyeon Lee, Hunpyo Ju, Junkyu Han, Namyun Kim, Jinmo Jeong, Sungbum Cho, Jae Hun Seol and 1 more

Open access · bronzeAbstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 65 citations in OpenAlex.

  1. Differential Tissue-Coupled Powering for Battery-Free Injectable Electroceuticals.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Review
  10. Subcutaneous power supply by NIR-II light.Nature communications · 2022
    Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Juho KimSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.ORCID 0000-0002-0413-9777
Jimin SeoSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Dongwuk JungSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.ORCID 0000-0001-8732-8487
Taeyeon LeeSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Hunpyo JuSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Junkyu HanSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Namyun KimSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Jinmo JeongSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Sungbum ChoSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Jae Hun SeolSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea.
Jongho LeeSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), 61005 Gwangju, Republic of Korea; jong@gist.ac.kr.ORCID 0000-0003-0398-4220
Gwangju Institute of Science and Technology · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent advances in soft materials and mechanics activate development of many new types of electrical medical implants. Electronic implants that provide exceptional functions, however, usually require more electrical power, resulting in shorter period of usages although many approaches have been suggested to harvest electrical power in human bodies by resolving the issues related to power density, biocompatibility, tissue damage, and others. Here, we report an active photonic power transfer approach at the level of a full system to secure sustainable electrical power in human bodies. The active photonic power transfer system consists of a pair of the skin-attachable photon source patch and the photovoltaic device array integrated in a flexible medical implant. The skin-attachable patch actively emits photons that can penetrate through live tissues to be captured by the photovoltaic devices in a medical implant. The wireless power transfer system is very simple, e.g., active power transfer in direct current (DC) to DC without extra circuits, and can be used for implantable medical electronics regardless of weather, covering by clothes, in indoor or outdoor at day and night. We demonstrate feasibility of the approach by presenting thermal and mechanical compatibility with soft live tissues while generating enough electrical power in live bodies through

Indexed as

Heart-Assist DevicesPhotonsWearable Electronic DevicesAnimalsHeart RateMiceSkin Physiological PhenomenaTransducersWireless Technologybioelectronicsbiomedical implantsflexible electronicsphotonic power transfer

Identifiers

PMID32632002
PMCPMC7382277
OpenAlexW3039974818

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.