Evidence map›Paper›PMID 32630829›Full record

ArticleSensors (Basel, Switzerland)2020

Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine.

Michael Leitner, Hannah Seferovic, Sarah Stainer, Boris Buchroithner, Christian H Schwalb, Alexander Deutschinger, Andreas Ebner

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Rational nanoparticle design: Optimization using insights from experiments and mathematical models.Journal of controlled release : official journal of the Controlled Release Society · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michael LeitnerInstitute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
Hannah SeferovicInstitute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
Sarah StainerInstitute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
Boris BuchroithnerInstitute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
Christian H SchwalbGETec Microscopy GmbH, Seestadtstraße 27/Top 27, 1220 Vienna, Austria.
Alexander DeutschingerSCL-Sensor.Tech. Fabrication GmbH, Seestadtstraße 27/Top 27, 1220 Vienna, Austria.
Andreas EbnerInstitute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.ORCID 0000-0001-5615-7590

Funding

European Regional Development Fund 2018-98292
6 · The paper itself

Abstract

Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible with conventional AFMs due to limitations caused by the optical readout. Here, we show a promising approach based on self-sensing cantilevers (SSC) as a replacement for optical readout in biological AFM imaging. Piezo-resistors, in the form of a Wheatstone bridge, are embedded into the cantilever, whereas two of them are placed at the bending edge. This enables the deflection of the cantilever to be precisely recorded by measuring the changes in resistance. Furthermore, the conventional acoustic or magnetic vibration excitation in intermittent contact mode can be replaced by a thermal excitation using a heating loop. We show further developments of existing approaches enabling stable measurements in turbid liquids. Different readout and excitation methods are compared under various environmental conditions, ranging from dry state to human blood. To demonstrate the applicability of our laser-free bio-AFM for nanomedical research, we have selected the hemostatic process of blood coagulation as well as ultra-flat red blood cells in different turbid fluids. Furthermore, the effects on noise and scanning speed of different media are compared. The technical realization is shown (1) on a conventional optical beam deflection (OBD)-based AFM, where we replaced the optical part by a new SSC nose cone, and (2) on an all-electric AFM, which we adapted for measurements in turbid liquids.

Indexed as

AcousticsMicroscopy, Atomic ForceNanomedicineHumansAFSEMall electric AFMbloodelectrical readoutpiezoresistive cantileverplateletself-actuatingself-sensing

Identifiers

PMID32630829
PMCPMC7374447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.