Evidence map›Paper›PMID 32629848›Full record

ArticleMicromachines2020

A 3D-Printed Modular Microreservoir for Drug Delivery.

Farzad Forouzandeh, Nuzhet N Ahamed, Meng-Chun Hsu, Joseph P Walton, Robert D Frisina, David A Borkholder

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. A review of peristaltic micropumps.Sensors and actuators. A, Physical · 2021
    Article
  8. Article
  9. Article
  10. Microtechnologies for inner ear drug delivery.Current opinion in otolaryngology & head and neck surgery · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Farzad ForouzandehMicrosystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
Nuzhet N AhamedMicrosystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
Meng-Chun HsuMicrosystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
Joseph P WaltonDepartment of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA.
Robert D FrisinaDepartment of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA.
David A BorkholderMicrosystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
Rochester Institute of Technology · USUniversity of South Florida · US

Funding

Enabling Microsystem Technologies for Advanced Drug DeliveryR01DC014568 · NIDCD · ROCHESTER INSTITUTE OF TECHNOLOGY · PI BORKHOLDER, DAVID A, FRISINA, ROBERT D · 2015 to 2019
$2.7M
NIDCD NIH HHS R01 DC014568
6 · The paper itself

Abstract

Reservoir-based drug delivery microsystems have enabled novel and effective drug delivery concepts in recent decades. These systems typically comprise integrated storing and pumping components. Here we present a stand-alone, modular, thin, scalable, and refillable microreservoir platform as a storing component of these microsystems for implantable and transdermal drug delivery. Three microreservoir capacities (1, 10, and 100 µL) were fabricated with 3 mm overall thickness using stereolithography 3D-printing technology, enabling the fabrication of the device structure comprising a storing area and a refill port. A thin, preformed dome-shaped storing membrane was created by the deposition of parylene-C over a polyethylene glycol sacrificial layer, creating a force-free membrane that causes zero forward flow and insignificant backward flow (2% of total volume) due to membrane force. A septum pre-compression concept was introduced that enabled the realization of a 1-mm-thick septa capable of ~65000 leak-free refill punctures under 100 kPa backpressure. The force-free storing membrane enables using normally-open micropumps for drug delivery, and potentially improves the efficiency and precision of normally-closed micropumps. The ultra-thin septum reduces the thickness of refillable drug delivery devices, and is capable of thousands of leak-free refills. This modular and scalable device can be used for drug delivery in different laboratory animals and humans, as a sampling device, and for lab-on-a-chip and point-of-care diagnostics applications.

Indexed as

3D-printingdrug deliveryimplantablemicroreservoirmodular microfluidicstransdermal

Identifiers

PMID32629848
PMCPMC7407798
OpenAlexW3038987035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked