ArticleMicromachines2020
Micro Water Flow Measurement Using a Temperature-Compensated MEMS Piezoresistive Cantilever.
Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications.Sensors (Basel, Switzerland) · 2025Article
- Rational Design of Flexible Mechanical Force Sensors for Healthcare and Diagnosis.Materials (Basel, Switzerland) · 2023Review
- Temperature Dependence of the Beating Frequency of hiPSC-CMs Using a MEMS Force Sensor.Sensors (Basel, Switzerland) · 2023Article
- Bio-Inspired Micromachined Volumetric Flow Sensor with a Big Dynamic Range for Intravenous Systems.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this study, we propose a microelectromechanical system (MEMS) force sensor for microflow measurements. The sensor is equipped with a flow sensing piezoresistive cantilever and a dummy piezoresistive cantilever, which acts as a temperature reference. Since the dummy cantilever is also in the form of a thin cantilever, the temperature environment of the dummy sensor is almost identical to that of the sensing cantilever. The temperature compensation effect was measured, and the piezoresistive cantilever was combined with a gasket jig to enable the direct implementation of the piezoresistive cantilever in a flow tube. The sensor device stably measured flow rates from 20 μL/s to 400 μL/s in a silicon tube with a 2-mm inner diameter without being disturbed by temperature fluctuations.