Evidence map›Paper›PMID 32627580›Full record

ArticleJournal of diabetes science and technology2021

Evaluation of a Novel Noninvasive Blood Glucose Monitor Based on Mid-Infrared Quantum Cascade Laser Technology and Photothermal Detection.

Thorsten Lubinski, Bartosz Plotka, Sergius Janik, Luca Canini, Werner Mäntele

Open access · hybridAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 42 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. The Perils of Molecular Interpretations from Vibrational Spectra of Complex Samples.Angewandte Chemie (International ed. in English) · 2024
    Review
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Thorsten LubinskiDiaMonTech AG, Berlin, Germany.
Bartosz PlotkaDiaMonTech AG, Berlin, Germany.
Sergius JanikDiaMonTech AG, Berlin, Germany.
Luca CaniniDiaMonTech AG, Berlin, Germany.
Werner MänteleDiaMonTech AG, Berlin, Germany.ORCID 0000-0002-8964-1319
Goethe University Frankfurt · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA prototype of a noninvasive glucometer combining skin excitation by a mid-infrared quantum cascade laser with photothermal detection was evaluated in glucose correlation tests including 100 volunteers (41 people with diabetes and 59 healthy people).

methodsInvasive reference measurements using a clinical glucometer and noninvasive measurements at a finger of the volunteer were simultaneously recorded in five-minute intervals starting from fasting glucose values for healthy subjects (low glucose values for diabetes patients) over a two-hour period. A glucose range from >50 to <350 mg/dL was covered. Machine learning algorithms were used to predict glucose values from the photothermal spectra. Data were analyzed for the average percent disagreement of the noninvasive measurements with the clinical reference measurement and visualized in consensus error grids.

results98.8% (full data set) and 99.1% (improved algorithm) of glucose results were within Zones A and B of the grid, indicating the highest accuracy level. Less than 1% of the data were in Zone C, and none in Zone D or E. The mean and median percent differences between the invasive as a reference and the noninvasive method were 12.1% and 6.5%, respectively, for the full data set, and 11.3% and 6.4% with the improved algorithm.

conclusionsOur results demonstrate that noninvasive blood glucose analysis combining mid-infrared spectroscopy and photothermal detection is feasible and comparable in accuracy with minimally invasive glucometers and finger pricking devices which use test strips. As a next step, a handheld version of the present device for diabetes patients is being developed.

Indexed as

Blood GlucoseLasers, SemiconductorBlood Glucose Self-MonitoringGlucoseHumansTechnologyBlood GlucoseGlucosemid-IR spectroscopynoninvasive blood glucose analysisphotothermal detectionquantum cascade laser (QCL)

Identifiers

PMID32627580
PMCPMC7780361
OpenAlexW3040276921

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.