Evidence map›Paper›PMID 32621214›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2021

Initial multicenter experience with a new high-density coloring module: impact for complex atrial arrhythmias interpretation.

Grégoire Massoullié, Ghassan Moubarak, Olivier Thomas, Antoine Da Costa, Vincent Roger, Julio Justo, Alexis Mechulan, Romain Eschalier, John Silberbauer, Marius Andronache

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Outcomes of catheter ablation of atrial tachyarrhythmia guided exclusively by activation mapping.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Grégoire MassoulliéCardiology Department, CHU Clermont-Ferrand, Clermont University, ISIT-CaVITI, 58 rue Montalembert, 63000 CHU, Clermont-Ferrand, France. gmassoullie@chu-clermontferrand.fr.ORCID http://orcid.org/0000-0002-9547-0835
Ghassan MoubarakDepartment of Electrophysiology and Pacing, Centre Médico-Chirurgical Ambroise Paré, Neuilly-sur-Seine, France.
Olivier ThomasDepartment of Electrophysiology and Pacing, Centre Médico-Chirurgical Ambroise Paré, Neuilly-sur-Seine, France.
Antoine Da CostaDivision of Cardiology, Jean Monnet University, Saint-Etienne, France.
Vincent RogerBiosense Webster, Issy-les-Moulineaux, France.
Julio JustoRoyal Sussex County Hospital, Brighton, UK.
Alexis MechulanDepartment of Cardiology, CH Clairval, Marseille, France.
Romain EschalierCardiology Department, CHU Clermont-Ferrand, Clermont University, ISIT-CaVITI, 58 rue Montalembert, 63000 CHU, Clermont-Ferrand, France.
John SilberbauerRoyal Sussex County Hospital, Brighton, UK.
Marius AndronacheCardiology Department, CHU Clermont-Ferrand, Clermont University, ISIT-CaVITI, 58 rue Montalembert, 63000 CHU, Clermont-Ferrand, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHigh-density automated mapping of complex atrial tachycardias (ATs) requires accurate assessment of activation maps. A new local activation display module (HD coloring, Biosense Webster®) provides higher map resolution, a better delineation of potential block reducing color interpolation, and a new propagation display. We evaluated the accuracy of a dedicated local activation display compared with standard algorithm.

methodsHigh-density maps from 10 AT were collected with a multipolar catheter and were displayed with standard activation or HD coloring. Six expert operators retrospectively analyzed activation maps and were asked to define (1) the tachycardia mechanism, (2) ablation target, and (3) level of difficulty to interpret those maps.

resultsUsing HD coloring, operators were able to reach a correct diagnosis in 93% vs. 63%, p < 0.05 compared to standard activation maps. Time to diagnosis was shorter 1.9 ± 1.0 min vs. 3.9 ± 2.1 min, p < 0.05. Confidence level would have allowed ablation without necessity for entrainment maneuvers in 87% vs. 53%, p < 0.05. Operators would have needed to remap or proceed with multiple entrainments in 3% vs. 13% of cases, p < 0.05. Finally, ablation strategy was more accurately identified in 97% vs. 67%, p < 0.05.

conclusionActivation mapping with the new HD coloring module allowed a more accurate, reliable, and faster interpretation of complex ATs mechanisms compared to standard activation maps.

Indexed as

Catheter AblationTachycardia, SupraventricularElectrophysiologic Techniques, CardiacHumansRetrospective StudiesTachycardiaAblationAtrial tachycardiaHigh-resolution mapping

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.