ArticleCardiovascular intervention and therapeutics2021
Early vascular response of ultra-thin bioresorbable polymer sirolimus-eluting stents assessed by optical frequency domain imaging: the EVALUATION study.
Article in Cardiovascular intervention and therapeutics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The ultrathin-strut everolimus-eluting stent in a real-world population: the Everythin multicenter registry.REC, interventional cardiologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to evaluate the early vascular response of ultra-thin strut bioresorbable polymer sirolimus-eluting stents (BP SES) using optical frequency domain imaging (OFDI). Ultra-thin strut BP SES have superior outcomes in terms of efficacy and safety endpoints when compared to other thin strut new-generation stents. However, the factors contributing to the superiority of BP SES over other thin strut new-generation stents are unclear. A total of 32 patients with multivessel disease requiring staged procedures at 1 month were enrolled from 3 cardiovascular institutions; of these, 31 were immediately assessed by OFDI (n = 31). All patients were assessed at 1 month after ultra-thin strut BP SES implantation. The primary endpoint was % of uncovered struts. A total of 1723 cross sections (17,014 struts) were analyzed at baseline and 1 month after percutaneous coronary intervention. The % uncovered struts at 1-month follow-up was 7.7% (4.0, 13.8). Furthermore, the covered strut % (88.4% and 80.4%, P = 0.013) and malapposition rate (2.7% and 4.3%, P = 0.012) were significantly different between the 60-μm and 80-μm stents. Ultra-thin strut BP SES implantation may feasibly achieve early vascular responses due to the ultra-thin struts. This may ultimately lead to lower stent thrombosis and target lesion failure rates.Clinical trial registration University Hospital Medical Information Network Clinical Trials Registry (No. UMIN000033406).
Indexed as
Identifiers
32621170What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.