ArticleUltrasonics2020
Minimally invasive therapeutic ultrasound: Ultrasound-guided ultrasound ablation in neuro-oncology.
Article in Ultrasonics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 23 citations in OpenAlex.
- Regulation of the brain tumor microenvironment by focused ultrasound.Molecular therapy. Oncology · 2025Review
- Surgical Management of Brain Tumors with Focused Ultrasound.Current oncology (Toronto, Ont.) · 2023Review
- Clinical value of pulmonary congestion detection by lung ultrasound in patients with chronic heart failure.Clinical cardiology · 2021Review
- A Robotically Steerable Guidewire With Forward-Viewing Ultrasound: Development of Technology for Minimally-Invasive Imaging.IEEE transactions on bio-medical engineering · 2021Article
- A MINIATURE LASER SPECKLE CONTRAST IMAGER FOR MONITORING OF THE NEURO-MODULATORY EFFECT OF TRANSCRANIAL FOCUSED ULTRASOUND STIMULATION.Proceedings of the ... Design of Medical Devices Conference. Design of Medical Devices Conference · 2021Article
- DESIGN AND FABRICATION OF A FOCUSED ULTRASOUND DEVICE FOR MINIMALLY-INVASIVE NEUROSURGERY: REPORTING A SECOND, MINIATURIZED AND MR-COMPATIBLE PROTOTYPE WITH STEERING CAPABILITIES.Proceedings of the ... Design of Medical Devices Conference. Design of Medical Devices Conference · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
18 authors at 2 institutions in 1 country.
Funding
Abstract
introductionTo improve patient outcomes (eg, reducing blood loss and infection), practitioners have gravitated toward noninvasive and minimally invasive surgeries (MIS), which demand specialized toolkits. Focused ultrasound, for example, facilitates thermal ablation from a distance, thereby reducing injury to surrounding tissue. Focused ultrasound can often be performed noninvasively; however, it is more difficult to carry out in neuro-oncological tumors, as ultrasound is dramatically attenuated while propagating through the skull. This shortcoming has prompted exploration of MIS options for intracranial placement of focused ultrasound probes, such as within the BrainPath™ (NICO Corporation, Indianapolis, IN). Herein, we present the design, development, and in vitro testing of an image-guided, focused ultrasound prototype designed for use in MIS procedures. This probe can ablate neuro-oncological lesions despite its small size. MATERIALS &
methodsPreliminary prototypes were iteratively designed, built, and tested. The final prototype consisted of three 8-mm-diameter therapeutic elements guided by an imaging probe. Probe functionality was validated on a series of tissue-mimicking phantoms.
resultsLesions were created in tissue-mimicking phantoms with average dimensions of 2.5 × 1.2 × 6.5 mm and 3.4 × 3.25 × 9.36 mm after 10- and 30-second sonification, respectively. 30 s sonification with 118 W power at 50% duty cycle generated a peak temperature of 68 °C. Each ablation was visualized in real time by the built-in imaging probe.
conclusionWe developed and validated an ultrasound-guided focused ultrasound probe for use in MIS procedures. The dimensional constraints of the prototype were designed to reflect those of BrainPath trocars, which are MIS tools used to create atraumatic access to deep-seated brain pathologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.