ArticleCurrent eye research2021
A Comparison of Applanation and Rebound Tonometers in Young Chicks.
Article in Current eye research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 9 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo assess the validity of and compare applanation and rebound tonometry readings of intraocular pressure in alert normal chicks from ages 3 to 45 days.
methodsIntraocular pressures (IOPs) were measured weekly in awake White Leghorn chicks, from ages 3-45 days (n = 22-30 per age group), with both applanation Tono-Pen and rebound TonoLab tonometers. Three repeated measurements on individual eyes were used to derive variance data for both instruments at each age. Calibration curves were also derived for each instrument and each age, weekly from ages 10-45 days (n = 3-4 per age group), from
resultsThe TonoLab showed less within measurement variability, but more variability with age, than the Tono-Pen. The coefficient of variation ranged from 3.8-8.3% for the TonoLab, compared to 11.0-19.7% for the Tono-Pen across all ages. For the youngest, 3 day-old chicks, mean IOPs recorded with the Tono-Pen and TonoLab were not significantly different (17.0 ± 5.6 and 15.2 ± 3.7 mmHg, respectively,
conclusionsBoth the Tono-Pen and TonoLab gave IOP readings that differed from manometry settings in normal young chicks over some or all of the ages tested. These results reinforce the importance of calibrating clinical tonometers in animal studies involving IOP as a key variable.
Indexed as
Identifiers
What OpenQuestion holds