ArticleAnalytical methods : advancing methods and applications2020
Optimization of graphene oxide-modified carbon-fiber microelectrode for dopamine detection.
Article in Analytical methods : advancing methods and applications, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 19 citations in OpenAlex.
- Optimization of Subsecond Estradiol Detection through Analysis of Surface-Analyte Interactions.ACS electrochemistry · 2026Article
- Metal Organic Framework-Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection.ChemElectroChem · 2026Article
- Stabilized carbon coating on microelectrodes for scalable and interoperable neurotransmitter sensing.Nature communications · 2025Article
- Real samples sensitive dopamine sensor based on poly 1,3-benzothiazol-2-yl((4-carboxlicphenyl)hydrazono)acetonitrile on a glassy carbon electrode.Scientific reports · 2024Article
- Surface-Roughened Graphene Oxide Microfibers Enhance Electrochemical Reversibility.Langmuir : the ACS journal of surfaces and colloids · 2024Article
- Waste Coffee Ground-Derived Porous Carbon for Neurochemical Detection.ACS sensors · 2024Article
- Dopamine Measurement Using Engineered CNT-CQD-Polymer Coatings on Pt Microelectrodes.Sensors (Basel, Switzerland) · 2024Article
- Editors' Choice-Review-The Future of Carbon-Based Neurochemical Sensing: A Critical Perspective.ECS sensors plus · 2023Review
- The Roadmap of Graphene-Based Sensors: Electrochemical Methods for Bioanalytical Applications.Biosensors · 2022Review
- Carbon microelectrodes with customized shapes for neurotransmitter detection: A review.Analytica chimica acta · 2022Review
- Porous Carbon Nanofiber-Modified Carbon Fiber Microelectrodes for Dopamine Detection.ACS applied nano materials · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
Graphene oxide (GO) is a carbon-based material that is easily obtained from graphite or graphite oxide. GO has been used broadly for electrochemistry applications and our hypothesis is that GO coating a carbon-fiber microelectrode (CFME) will increase the sensitivity for dopamine by providing more adsorption sites due to the enhancement of oxygen functional groups. Here, we compared drop casting, dip coating, and electrodeposition methods to directly coat commercial GO on CFME surfaces. Dip coating did not result in much GO coating and drop casting resulted in large agglomerations that produced noisy signals and slow rise times. Electrodeposition method with cyclic voltammetry increase the current for dopamine and this method was the most reproducible and had the least noise compared to the other two coating methods. The optimized method used a triangular waveform scanned from -1.2 V to 1.5 V at 100 mV/s for 5 cycles in 0.2 mg/mL GO in water. With fast-scan cyclic voltammetry (FSCV), the optimized GO/CFME enhanced the dopamine oxidation peak two-fold. The sensitivity of the modified electrode is 41±2 nA/μM with a linear range from 25 nM to 1 μM, and a limit of detection of 11 nM. The optimized electrodes were used to detect electrically-stimulated dopamine in brain slices to demonstrate their performance in tissue. Thus, GO can be used to enhance the sensitivity of electrodes for dopamine and improve biological measurements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.