Evidence map›Paper›PMID 32617079›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

Retrospective study on performance of constancy check device in Linac beam monitoring using Statistical Process Control.

Bipasha Pal, Angshuman Pal, Suresh Das, Soura Palit, Papai Sarkar, Subhayan Mondal, Suman Mallik, Jyotirup Goswami, Sayan Das, Arijit Sen and 1 more

Open access · diamondAbstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.3field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Bipasha PalNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Angshuman PalDepartment of Mechanical Engineering, Jadavpur University, 188 Raja SC Mallick Road, Kolkata 700032, West Bengal, India.
Suresh DasNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Soura PalitNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Papai SarkarNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Subhayan MondalNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Suman MallikNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Jyotirup GoswamiNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Sayan DasNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Arijit SenNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Monidipa MondolNarayana Superspeciality Hospital, 120/1 Andul Road, Howrah 711103, West Bengal, India.
Nethradhama Superspeciality Eye Hospital · INJadavpur University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo examine the application of Statistical Process Control (SPC) and Ishikawa diagrams for retrospective evaluation of machine Quality Assurance (QA) performance in radiotherapy.

backgroundSPC is a popular method for supplementing the performance of QA techniques in healthcare. This work investigates the applicability of SPC techniques and Ishikawa charts in machine QA. MATERIALS AND

methodsSPC has been applied to recommend QA limits on the particular beam parameters using the QUICKCHECK

resultsShewhart charts and EWMA charts applied could detect loss in control in one variable in the 6 MV beams and in all four variables in 10 MV beams. CUSUM charts detected offsets in the readings. The Ishikawa chart exhaustively included the possible errors that lead to loss of control.

conclusionSPC is proven to be effective for detection of loss in control in machine QA. The Ishikawa chart provides the set of probable root causes of machine error useful while troubleshooting.

Indexed as

Ishikawa diagramQuality assuranceRadiotherapyShewhart chartStatistical process control

Identifiers

PMID32617079
PMCPMC7315042
OpenAlexW2996213332

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.