Evidence map›Paper›PMID 32613315›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2021

Eligibility for subcutaneous implantable cardioverter-defibrillator in patients with left ventricular assist device.

Christos Zormpas, Jörg Eiringhaus, Henrike A K Hillmann, Stephan Hohmann, Johanna Müller-Leisse, Jan D Schmitto, Christian Veltmann, David Duncker

Open access · hybridAbstract read
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. [Practical guidance for the implantation of non-transvenous ICD systems].Herzschrittmachertherapie & Elektrophysiologie · 2024
    Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Christos ZormpasHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
Jörg EiringhausHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
Henrike A K HillmannHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
Stephan HohmannHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
Johanna Müller-LeisseHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
Jan D SchmittoDepartment of Cardiac, Thoracic, Transplant and Vascular Surgery, Hannover Medical School, Hanover, Germany.
Christian VeltmannHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
David DunckerHannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany. duncker.david@mh-hannover.de.ORCID http://orcid.org/0000-0003-2996-6338
Medizinische Hochschule Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe subcutaneous implantable cardioverter-defibrillator (S-ICD) could be a promising alternative to the conventional transvenous ICD in patients with LVAD due to its reduced risk of infection. However, surface ECG is altered following LVAD implantation and, since S-ICD detection is based on surface ECG, S-ICD could be potentially affected. The aim of the present study was to analyze S-ICD eligibility in patients with LVAD.

methodsSeventy-five patients implanted with an LVAD were included in this prospective single-center study. The ECG-based screening test and the automated screening test were performed in all patients.

resultsFifty-five (73.3%) patients had either a positive ECG-based or automated screening test. Out of these, 28 (37.3%) patients were found eligible for S-ICD implantation with both screening tests performed. ECG-based screening test was positive in 50 (66.6%) patients; automated screening test was positive in 33 (44.0%) patients. Three ECG-based screening tests could not be evaluated due to artifacts. With the automated screening test, in 9 (12.0%) patients, the test yielded no result.

conclusionsPatients implanted with an LVAD showed lower S-ICD eligibility rates compared with patients without LVAD. With an S-ICD eligibility rate of maximal 73.3%, S-ICD therapy may be a feasible option in these patients. Nevertheless, S-ICD implantation should be carefully weighed against potential device-device interference. Prospective studies regarding S-ICD eligibility before and after LVAD implantation are required to further elucidate the role of S-ICD therapy in this population.

Indexed as

Defibrillators, ImplantableHeart-Assist DevicesDeath, Sudden, CardiacElectrocardiographyHumansProspective StudiesDevice-device interferenceICDLVADS-ICDS-ICD screening test

Identifiers

PMID32613315
PMCPMC7925469
OpenAlexW3038386386

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.