Evidence map›Paper›PMID 32611427›Full record

ArticleCardiovascular ultrasound2020

Feasibility and accuracy of a novel automated three-dimensional ultrasonographic analysis system for abdominal aortic aneurysm: comparison with two-dimensional ultrasonography and computed tomography.

In-Jeong Cho, Jinyong Lee, Jinki Park, Sang-Eun Lee, Chul-Min Ahn, Young-Guk Ko, Donghoon Choi, Hyuk-Jae Chang

Open access · goldAbstract readComparative Study
In one paragraph

Article in Cardiovascular ultrasound, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

In-Jeong ChoDivision of Cardiology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, College of Medicine, Ewha Womans University, Seoul, Republic of Korea.
Jinyong LeeUltrasound R&D Group, Samsung Medison Co., Ltd, Seoul, Republic of Korea.
Jinki ParkUltrasound R&D Group, Samsung Medison Co., Ltd, Seoul, Republic of Korea.
Sang-Eun LeeDivision of Cardiology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, College of Medicine, Ewha Womans University, Seoul, Republic of Korea.
Chul-Min AhnDivision of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Young-Guk KoDivision of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Donghoon ChoiDivision of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Hyuk-Jae ChangDivision of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea. hjchang@yuhs.ac.
Yonsei University · KREwha Womans University · KRSamsung Medison (South Korea)Samsung (South Korea) · KR

Funding

Ministry of Science, ICT and Future Planning 2012027176
6 · The paper itself

Abstract

backgroundAccurate measurement of the maximum aortic diameter (Dmax) is crucial for patients with abdominal aortic aneurysm (AAA). Aortic computed tomography (CT) provides accurate Dmax values by three-dimensional (3-D) reconstruction but may cause nephrotoxicity because of contrast use and radiation hazard. We aimed to evaluate the accuracy of a novel semi-automated 3-D ultrasonography (3-D US) system compared with that of CT as a reference.

methodsPatients with AAA (n = 59) or individuals with normal aorta (n = 18) were prospectively recruited in an outpatient setting. Two-dimensional ultrasonography (2-D US) and 3-D US images were acquired with a single-sweep volumetric transducer. The analysis was performed offline with a software. Dmax and the vessel area of the Dmax slice were measured with 2-D US, 3-D US, and CT. The lumen and thrombus areas of the Dmax slice were also measured in 40 patients with intraluminal thrombus. Vessel and thrombus volumes were measured using 3-D US and CT.

resultsThe Dmax values from 3-D US demonstrated better agreement (R

conclusionsOur novel semi-automated 3-D US analysis system provides more accurate Dmax values than 2-D US and provides precise volumetric data, which were not evaluable with 2-D US. The application of the semi-automated 3-D US analysis system in abdominal aorta assessment is easy and accurate.

Indexed as

AgedAorta, AbdominalAortic Aneurysm, AbdominalFeasibility StudiesFemaleFollow-Up StudiesHumansImaging, Three-DimensionalMaleMiddle AgedProspective StudiesTomography, X-Ray ComputedUltrasonographyAbdominal aortic aneurysmSoftware validationThree-dimensional imaging

Identifiers

PMID32611427
PMCPMC7330975
OpenAlexW3038899216

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked