Evidence map›Paper›PMID 32610555›Full record

ArticleSensors (Basel, Switzerland)2020

Towards Optical Imaging for Spine Tracking without Markers in Navigated Spine Surgery.

Francesca Manni, Adrian Elmi-Terander, Gustav Burström, Oscar Persson, Erik Edström, Ronald Holthuizen, Caifeng Shan, Svitlana Zinger, Fons van der Sommen, Peter H N de With

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Vertebrae segmentation in reduced radiation CT imaging for augmented reality applications.International journal of computer assisted radiology and surgery · 2022
    Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Francesca ManniDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands.ORCID 0000-0003-0470-2299
Adrian Elmi-TeranderDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm SE-171 46, Sweden & Department of Neurosurgery, Karolinska University Hospital, Stockholm SE-171 46, Sweden.ORCID 0000-0002-3776-6136
Gustav BurströmDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm SE-171 46, Sweden & Department of Neurosurgery, Karolinska University Hospital, Stockholm SE-171 46, Sweden.
Oscar PerssonDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm SE-171 46, Sweden & Department of Neurosurgery, Karolinska University Hospital, Stockholm SE-171 46, Sweden.
Erik EdströmDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm SE-171 46, Sweden & Department of Neurosurgery, Karolinska University Hospital, Stockholm SE-171 46, Sweden.
Ronald HolthuizenPhilips Healthcare, Best 5684 PC, The Netherlands.
Caifeng ShanPhilips Research, High Tech Campus 36, 5656 AE Eindhoven, The Netherlands.ORCID 0000-0002-2131-1671
Svitlana ZingerDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands.
Fons van der SommenDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands.ORCID 0000-0002-3593-2356
Peter H N de WithDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands.
Eindhoven University of Technology · NLKarolinska University Hospital · SEPhilips (Netherlands) · NL

Funding

Electronic Components and Systems for European Leadership 692470
6 · The paper itself

Abstract

Surgical navigation systems are increasingly used for complex spine procedures to avoid neurovascular injuries and minimize the risk for reoperations. Accurate patient tracking is one of the prerequisites for optimal motion compensation and navigation. Most current optical tracking systems use dynamic reference frames (DRFs) attached to the spine, for patient movement tracking. However, the spine itself is subject to intrinsic movements which can impact the accuracy of the navigation system. In this study, we aimed to detect the actual patient spine features in different image views captured by optical cameras, in an augmented reality surgical navigation (ARSN) system. Using optical images from open spinal surgery cases, acquired by two gray-scale cameras, spinal landmarks were identified and matched in different camera views. A computer vision framework was created for preprocessing of the spine images, detecting and matching local invariant image regions. We compared four feature detection algorithms, Speeded Up Robust Feature (SURF), Maximal Stable Extremal Region (MSER), Features from Accelerated Segment Test (FAST), and Oriented FAST and Rotated BRIEF (ORB) to elucidate the best approach. The framework was validated in 23 patients and the 3D triangulation error of the matched features was < 0 . 5 mm. Thus, the findings indicate that spine feature detection can be used for accurate tracking in navigated surgery.

Indexed as

Augmented RealityOptical ImagingSurgery, Computer-AssistedSurgical Navigation SystemsAlgorithmsHumansImaging, Three-DimensionalPhantoms, ImagingSpineimage analysis for markerless trackingimage-guided surgeryimage processingoptical sensingpatient trackingspinal surgery

Identifiers

PMID32610555
PMCPMC7374436
OpenAlexW3038118042

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.