Evidence map›Paper›PMID 32609088›Full record

ArticleActa orthopaedica et traumatologica turcica2020

Diagnostic accuracy of ultrasound in subscapularis tendon abnormalities and the importance of operator experience.

Uğur Toprak, Sefa Türkoğlu, Çiğdem Aydoğan, Emrah Kovalak, Suzan Saylısoy, Duygu Sıddıkoğlu, Akkan Mahmud

Open access · goldAbstract read
In one paragraph

Article in Acta orthopaedica et traumatologica turcica, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 6 institutions in 1 country.

Uğur ToprakDepartment of Radiology, Eskişehir Osmangazi University, School of Medicine, Eskişehir, Turkey.
Sefa TürkoğluClinic of Radiology, Denizli State Hospital, Denizli, Turkey.
Çiğdem AydoğanClinic of Physical treatment and Rehabilitation, Artvin State Hospital, Artvin, Turkey.
Emrah KovalakDepartment of Orthopaedics, Süleyman Demirel University, School of Medicine, Isparta, Turkey.
Suzan SaylısoyDepartment of Radiology, Eskişehir Osmangazi University, School of Medicine, Eskişehir, Turkey.
Duygu SıddıkoğluDepartment of Biostatistics, Ankara University, School of Medicine, Ankara, Turkey.
Akkan MahmudClinic of Pediatric Hematology, Lösante Hospital, Ankara, Turkey.
Eskişehir Osmangazi University · TRAnkara University · TRArtvin Coruh University · TRDenizli Devlet Hastanesi · TRMemorial Ankara Hospital · TRSüleyman Demirel University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to investigate the reasons behind the compliance, diagnostic success, and failure of ultrasound (US) examinations of two radiologists with reference to magnetic resonance imaging (MRI) in the abnormalities of subscapularis (SSC) tendon, including tendinosis.

methodsOne less experienced radiologist (operator-1) and one senior radiologist, experienced in the musculoskeletal US (operator-2), performed the shoulder US on 78 patients (mean age: 53.18 ± 10.89 [22-73] years), who had undergone MRI for routine reasons except malignancy, within 1-4 weeks of MRI. Tendinopathy, partial (PT), or full-thickness (FT) tears were recorded in the subscapularis. The thickness of the anterior and lateral soft tissues in the shoulder girdle was measured by MRI. The inter-operator agreement on the US results, the US-MRI compliance for each operator, and the relationship between the US-MRI compliance and tissue thickness were investigated.

resultsThe inter-operator agreement on the US findings was moderate. The US-MRI compliance was fair for operator-1, but substantial for operator-2. The circumferential soft tissue thickness and US-MRI compliance were not correlated (p>0.05). The interobserver agreement in US was moderate (K: 0.415). The US-MRI compliance was fair for operator-1 (K: 0.344) and substantial for operator-2 (K: 0.616). The accuracy rates for the differentiation of normal tendon, tendinosis, PT, and FT were 59%, 75%, 72%, and 100%, respectively, for operator-1 and 87%, 83%, 85%, and 100%, respectively, for operator-2. However, the respective sensitivity of operator-1 was 46%, 19%, 44%, and 100%; and operator-2 was 91%, 67%, 82%, and 100%. The diagnostic performance of operator-1 was lower, except for FT.

conclusionThe thickness of the surrounding tissue does not affect the US results. The differentiation between tendinosis and PT tear is difficult (more prominent in less experienced user); however, because this would not change the treatment choice, shoulder US is recommended after basic training in subscapularis pathologies. LEVEL OF EVIDENCE: Level II, Diagnostic.

Indexed as

Clinical CompetenceDiagnosis, DifferentialFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedOutcome Assessment, Health CareRotator CuffRotator Cuff InjuriesTendinopathyUltrasonography

Identifiers

PMID32609088
PMCPMC7444886
OpenAlexW3039374779

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.