Evidence map›Paper›PMID 32607664›Full record

ArticleEJNMMI physics2020

Performance assessment of the 2 γpositronium imaging with the total-body PET scanners.

P Moskal, D Kisielewska, R Y Shopa, Z Bura, J Chhokar, C Curceanu, E Czerwiński, M Dadgar, K Dulski, J Gajewski and 32 more

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
5.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 70 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

42 authors at 7 institutions in 5 countries.

P MoskalFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland. p.moskal@uj.edu.pl.
D KisielewskaFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland. dk.dariakisielewska@gmail.com.
R Y ShopaDepartment of Complex Systems, National Centre for Nuclear Research, Otwock-Świerk, 05-400, Poland.
Z BuraFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
J ChhokarFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
C CurceanuINFN, Laboratori Nazionali di Frascati, Frascati, 00044, Italy.
E CzerwińskiFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M DadgarFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
K DulskiFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
J GajewskiInstitute of Nuclear Physics PAN, Cracow, Poland.
A GajosFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M GorgolInstitute of Physics, Maria Curie-Skłodowska University, Lublin, 20-031, Poland.
R Del GrandeINFN, Laboratori Nazionali di Frascati, Frascati, 00044, Italy.
B C HiesmayrFaculty of Physics, University of Vienna, Vienna, 1090, Austria.
B JasińskaInstitute of Physics, Maria Curie-Skłodowska University, Lublin, 20-031, Poland.
K KacprzakFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
A KamińskaFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
Ł KapłonFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
H KarimiFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
G KorcylFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
P KowalskiDepartment of Complex Systems, National Centre for Nuclear Research, Otwock-Świerk, 05-400, Poland.
N KrawczykFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
W KrzemieńHigh Energy Physics Division, National Centre for Nuclear Research, Otwock-Świerk, 05-400, Poland.
T KozikFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
E KubiczFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
P Małczak2nd Department of General Surgery, Jagiellonian University Medical College, Cracow, Poland.
M MohammedFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
Sz NiedźwieckiFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M PałkaFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M Pawlik-NiedźwieckaFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M Pędziwiatr2nd Department of General Surgery, Jagiellonian University Medical College, Cracow, Poland.
L RaczyńskiDepartment of Complex Systems, National Centre for Nuclear Research, Otwock-Świerk, 05-400, Poland.
J RajFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
A RucińskiInstitute of Nuclear Physics PAN, Cracow, Poland.
S SharmaFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
S ShivaniFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M SilarskiFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
M SkurzokFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
E Ł StępieńFaculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, prof. Stanisława Łojasiewicza 11, Cracow, 30-348, Poland.
S VandenbergheDepartment of Electronics and Information Systems, MEDISIP, Ghent University-IBiTech, De Pintelaan 185 block B, Ghent, B-9000, Belgium.
W WiślickiHigh Energy Physics Division, National Centre for Nuclear Research, Otwock-Świerk, 05-400, Poland.
B ZgardzińskaInstitute of Physics, Maria Curie-Skłodowska University, Lublin, 20-031, Poland.
Jagiellonian University · PLNational Centre for Nuclear Research · PLMaria Curie-Skłodowska University · PLIstituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati · ITGhent University · BEUniversity of Mosul · IQUniversity of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn living organisms, the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511 keV photons. In this article, we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include the (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using 2γ annihilations and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner.

methodsSimulations are conducted assuming that radiopharmaceutical is labeled with

resultsThe estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences (2γ+γ

conclusionsOrtho-positronium mean lifetime imaging based on the annihilations into two photons and prompt gamma is shown to be feasible with the advent of the high sensitivity total-body PET systems and time resolution of the order of tens of picoseconds.

Indexed as

Medical imagingPETPositronium imagingTotal-body PET

Identifiers

PMID32607664
PMCPMC7326848
OpenAlexW3038407860

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked