The impact of the laser fiber-tissue distance on histological parameters in a porcine kidney model.

Mark Taratkin, Christopher Netsch, Dmitry Enikeev, Andreas J Gross, Thomas R W Herrmann, Dmitry Korolev, Ekaterina Laukhtina, Petr Glybochko, Benedikt Becker

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of urology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Mark TaratkinInstitute for Urology and Reproductive Health, Sechenov University, Moscow, Russia.
Christopher NetschDepartment of Urology, Asklepios Hospital Barmbek, Rübenkamp 220, 22291, Hamburg, Germany.
Dmitry EnikeevInstitute for Urology and Reproductive Health, Sechenov University, Moscow, Russia.
Andreas J GrossDepartment of Urology, Asklepios Hospital Barmbek, Rübenkamp 220, 22291, Hamburg, Germany.
Thomas R W HerrmannDepartment of Urology, Kantonsspital Frauenfeld, Frauenfeld, Switzerland.
Dmitry KorolevInstitute for Urology and Reproductive Health, Sechenov University, Moscow, Russia.
Ekaterina LaukhtinaInstitute for Urology and Reproductive Health, Sechenov University, Moscow, Russia.
Petr GlybochkoInstitute for Urology and Reproductive Health, Sechenov University, Moscow, Russia.
Benedikt BeckerDepartment of Urology, Asklepios Hospital Barmbek, Rübenkamp 220, 22291, Hamburg, Germany. ben.becker@asklepios.com.ORCID http://orcid.org/0000-0003-1105-1615
Sechenov University · RUAsklepios Klinik Barmbek · DEKantonsspital Frauenfeld · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the impact of the fiber-tissue distance on histological parameters in a porcine kidney model.

methodsFour lasers were tested at 60 W using a 600-µm bare-ended fiber: a continuous wave (cw) thulium fiber laser (TFL), a super pulsed (SP) TFL, a Ho:YAG laser, and a blue diode laser (BDL). All tissue samples were mounted on a motorized XY-translation stage. The fiber-tissue distance was changed within a range from 0to 6 mm. Ten incisions were made with each laser at each distance. Afterwards, the tissue samples were sliced with a microtome for lactate dehydrogenase staining to determine zones of thermal damage.

resultsIn contact mode, the largest incision depth was found for the cw TFL (1.7 ± 0.1 mm) compared to the SP TFL (1.0 ± 0.1 mm), BDL (0.9 ± 0.1 mm) and HoYAG laser (1.1 ± 0.1 mm), respectively. With regard to the coagulative properties, the SP TFL and the Ho:YAG laser showed comparable coagulation depths with 0.7 ± 0.1 and 0.6 ± 0.1 mm, respectively. At 2 mm fiber-tissue distance, the Ho:YAG laser was the only laser that vaporized tissue (incision depth: 0.2 ± 0.1 mm). The BDL was the only laser that caused coagulation at a distance of 3-5 mm.

conclusionOur results support the clinical observation that cw TFL must be defocused for best coagulation, while the coagulation depth of the SP TFL remains nearly constant within the range of 0-3 mm. Increasing the distance of the laser fiber to the tissue up to 5 mm did not cause significant differences with regard to coagulation depth using the BDL.

Indexed as

Lasers, SemiconductorLasers, Solid-StateThuliumAnimalsKidneyLaser TherapySwineThuliumBlue diode laserEx vivoLaserPorcine kidneyThulium fiber laser

Identifiers

PMID32607593
OpenAlexW3038238443

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.