ArticleJournal of neurogastroenterology and motility2020
Performing High-resolution Impedance Manometry After Endoscopy With Conscious Sedation Has Negligible Effects on Esophageal Motility Results.
Article in Journal of neurogastroenterology and motility, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 17 citations in OpenAlex.
- Virtual Reality for Pain Management During High-Resolution Manometry: A Randomized Clinical Trial.The Laryngoscope · 2024Trial
- Consensus on the Management of Anesthetic Agents During Digestive Motility Measurements and Proposal of a Standardized Protocol for Anesthesia (French Neuro Gastroenterology Group GFNG and Committee of Anesthetic French Experts).Neurogastroenterology and motility · 2026Article
- Gastrointestinal endoscopy for physiological assessment in functional gastrointestinal disorders: a perspective.Frontiers in medicine · 2026Article
- Article
- Endoscopic Sedation Type During FLIP Panometry Does Not Significantly Impact FLIP Motility Classification Relative to Manometry.Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2025Article
- The Esophageal Response to Distension on Functional Lumen Imaging Probe Panometry Is Minimally Changed by Conscious Sedation in Healthy Asymptomatic Subjects.Journal of neurogastroenterology and motility · 2025Article
- Article
- Sedation and Endoscopy-Assisted High-Resolution Manometry (SEA-HRM) in Patients Who Previously Failed Standard Esophageal Manometry.Diagnostics (Basel, Switzerland) · 2024Article
- Perioperative management protocol for pediatric endoluminal functional lumen imaging probe in esophageal motility disorders.Journal of pediatric gastroenterology and nutrition · 2024Article
- Piloting an intraoral pH device to track gastroesophageal reflux in adults.Scientific reports · 2024Article
- Technical Success in Performing Esophageal High-Resolution Manometry in Patients with an Epiphrenic Diverticulum.Dysphagia · 2024Article
- Nasal trumpet harmoniously improves tolerance to high-resolution impedance manometry catheter placement.Neurogastroenterology and motility · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 2 countries.
Funding
Abstract
Background/Aims: High-resolution manometry (HRM) performed without sedation is the standard procedure. However, some patients cannot tolerate transnasal placement of the manometry catheter. We aim to assess the practice of performing manometry after endoscopy with conscious sedation by evaluating its impact on esophageal motility findings. Methods: Twelve asymptomatic adult volunteers and 7 adult patients completed high-resolution impedance manometry (HRIM) approximately 1 hour after conscious sedation with midazolam and fentanyl (post-sedation) and again on a different day with no-sedation. The nosedation HRIM involved 2 series of swallows separated in time by 20 minutes (no-sedation-1 and no-sedation-2) for the volunteers; patients completed only 1 series of swallows for no-sedation HRM. Results: A motility diagnosis of normal motility was observed in all 12 volunteers post-sedation. Two volunteers had a diagnosis of borderline ineffective esophageal motility, one during the no-sedation-1 period and the other during the no-sedation-2 period; all of the other no-sedation HRIM studies yielded a normal motility diagnosis. Six of seven patients had the same diagnosis in both no-sedation and post-sedation HRM, including 1 distal esophageal spasm, 3 achalasia (2 type II and 1 type III), and 2 esophagogastric junction outflow obstruction. Only one patient's HRM classification changed from ineffective esophageal motility at no-sedation to normal esophageal motility at post-sedation. Conclusions: Performing HRIM after endoscopy with conscious sedation had minimal clinical impact on the motility diagnosis or motility parameters. Thus, this approach may be a viable alternative for patients who cannot tolerate unsedated catheter placement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.