Evidence map›Paper›PMID 32605554›Full record

ArticleBMC surgery2020

Design of custom-made navigational template of femoral head and pilot research in total hip resurfacing arthroplasty.

Jinlong Liang, Yonghui Zhao, Xinjian Gao, Xuewei Fang, Yongqing Xu, Sheng Lu

Open access · goldAbstract read
In one paragraph

Article in BMC surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jinlong LiangDepartment of Orthopedics, 920 Hospital of Joint Logistic Support Force, Kunming, 650032, China.
Yonghui ZhaoDepartment of Orthopedics, 920 Hospital of Joint Logistic Support Force, Kunming, 650032, China.
Xinjian GaoXi'an Jiaotong University, Xian, 710049, China.
Xuewei FangXi'an Jiaotong University, Xian, 710049, China.
Yongqing XuDepartment of Orthopedics, 920 Hospital of Joint Logistic Support Force, Kunming, 650032, China.
Sheng LuDepartment of orthopedics, the first people's hospital of yunnan province; Yunnan Provincial Key laboratory of digital orthopedics, Kunming, 650032, China. drlusheng@163.com.ORCID http://orcid.org/0000-0001-7532-8981
Xi'an Jiaotong University · CNFirst People's Hospital of Yunnan Province · CN

Funding

Applied Basic Research Key Project of Yunnan 2017ZF025
6 · The paper itself

Abstract

backgroundTo develop a novel custom-made navigational template for accurate prosthesis implantation in total hip resurfacing arthroplasty (THRA) by computer-aided technology.

methodsThe template was produced based on data preoperatively acquired from computed tomography (CT) scan. The position of the drill guide was obtained according to the anatomical axis of the femoral neck which was defined by the point of the femoral head center and another point of the femoral neck center. The final direction of the drill guide was confirmed by a valgus angle. The surface of the template was constructed based on the inverse of the femoral neck surface. Then the template was made of acrylate resin by using rapid prototyping (RP) technique. Finally, all the templates were verified in 17 cadavers arranged for THRA and postoperative medical images were employed to evaluate the accuracy and validity of the template.

resultsThe templates had achieved a high fitting with the femoral neck surface, and there were no guide failures. Postoperative evaluation revealed that the Kirschner-wires pass through the center of the femoral head and femoral neck, presenting a relative expected and acceptable valgus angle to the central axis of the femoral neck. The lateral offset showed the relative valgus angle achieved as expected, the horizontal offset showed that no obvious antero-posterior deviation occured. The comparison between the preoperative Neck-shaft angle (NSA) and the postoperative Stem-shaft angle (SSA) showed there is no significant difference(P > 0.05).

conclusionThe novel custom-made navigational template of femoral head can effectively assist surgeons for accurately implanting the femoral head components to the desired position in THRA.

Indexed as

Femur HeadAgedArthroplasty, Replacement, HipCadaverFemaleFemur NeckHumansImaging, Three-DimensionalMaleMiddle AgedPatient-Specific ModelingPilot ProjectsProsthesis DesignReproducibility of ResultsSurgery, Computer-AssistedTomography, X-Ray ComputedAnatomical axis of the femoral neckComputer assisted surgeryCustom-made navigational templateRapid prototypingTotal hip resurfacing Arthroplasty

Identifiers

PMID32605554
PMCPMC7325234
OpenAlexW3039315784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.