Evidence map›Paper›PMID 32605006›Full record

ArticleSensors (Basel, Switzerland)2020

Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor.

Ibrahim AlMohimeed, Yuu Ono

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Wearable Bioelectronics for Home-Based Monitoring and Treatment of Muscle Atrophy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  8. Article
  9. Article
  10. Emerging Wearable Ultrasound Technology.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Review
  11. Article
  12. Proof-of-principle study usingJournal of biosciences · 2024
    Article
  13. Review
  14. Article
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ibrahim AlMohimeedDepartment of Systems and Computer Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada.
Yuu OnoDepartment of Systems and Computer Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada.

Funding

Natural Sciences and Engineering Research Council of Canada RGPIN 2014-03672
6 · The paper itself

Abstract

Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness ( T h ), contraction time ( T c ), contraction velocity ( V c ), sustain time ( T s ), and half-relaxation ( T r ) provides valuable information for various medical applications. This paper presents a single-element wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters in A-mode ultrasonic data acquisition. The developed WUS was made of double-layer polyvinylidene fluoride (PVDF) piezoelectric polymer films with a simple and low-cost fabrication process. A flexible, lightweight, thin, and small size WUS would provide a secure attachment to the skin surface without affecting the muscle contraction dynamics of interest. The developed WUS was employed to monitor the contractions of gastrocnemius (GC) muscle of a human subject. The GC muscle contractions were evoked by the electrical muscle stimulation (EMS) at varying EMS frequencies from 2 Hz up to 30 Hz. The tissue thickness changes due to the muscle contractions were measured by utilizing a time-of-flight method in the ultrasonic through-transmission mode. The developed WUS demonstrated the capability to monitor the tissue thickness changes during the unfused and fused tetanic contractions. The tetanic progression level was quantitatively assessed using the parameter of the fusion index (FI) obtained. In addition, the contractile parameters ( T h , T c , V c , T s , and T r ) were successfully extracted from the measured tissue thickness changes. In addition, the unfused and fused tetanus frequencies were estimated from the obtained FI-EMS frequency curve. The WUS and ultrasonic method proposed in this study could be a valuable tool for inexpensive, non-invasive, and continuous monitoring of the skeletal muscle contractile properties.

Indexed as

Muscle ContractionUltrasonicsWearable Electronic DevicesElectric StimulationHumansMuscle, Skeletalelectrical muscle stimulationfusion indexmuscle contractile parameterspiezoelectric PVDF filmsingle-element ultrasonic sensorskeletal muscle monitoringtetanic contractionultrasonic transducerwearable and flexible ultrasonic sensor

Identifiers

PMID32605006
PMCPMC7374409

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.