Design and evaluation of a portable negative pressure hood with HEPA filtration to protect health care workers treating patients with transmissible respiratory infections.
Article in American journal of infection control, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 21 citations in OpenAlex.
- Effectiveness of a suction device for containment of pathogenic aerosols and droplets.PloS one · 2024Article
- Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response.Journal of medical devices · 2023Article
- Airborne transmission of biological agents within the indoor built environment: a multidisciplinary review.Air quality, atmosphere, & health · 2023Review
- A review of facilities management interventions to mitigate respiratory infections in existing buildings.Building and environment · 2022Article
- Article
- Computational modelling of an aerosol extraction device for use in COVID-19 surgical tracheotomy.Journal of aerosol science · 2022Article
- Bioinspiration as a method of problem-based STEM education: A case study with a class structured around the COVID-19 crisis.Ecology and evolution · 2021Article
- Containment of procedure-associated aerosols by an extractor tent: effect on nebulized drug particle dispersal.The Journal of hospital infection · 2021Article
- Aerosol drug delivery to tracheotomized patients with COVID-19: Pragmatic suggestions for clinicians.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo mitigate potential exposure of healthcare workers (HCWs) to SARS-CoV-2 via aerosol routes, we have developed a portable hood which not only creates a barrier between HCW and patient, but also utilizes negative pressure with filtration of aerosols by a high-efficiency particulate air filter. MATERIAL AND
methodsThe hood has iris-port openings for access to the patient, and an opening large enough for a patient's head and upper torso. The top of the hood is a high-efficiency particulate air filter connected to a blower to apply negative pressure. We determined the aerosol penetration from outside to inside in laboratory experiments.
resultsThe penetration of particles from within the hood to the breathing zones of HCWs outside the hood was near 10