Evidence map›Paper›PMID 32602958›Full record

ArticleMagnetic resonance in medicine2020

Three-dimensional inhomogeneous magnetization transfer with rapid gradient-echo (3D ihMTRAGE) imaging.

Gopal Varma, Fanny Munsch, Brian Burns, Guillaume Duhamel, Olivier M Girard, Arnaud Guidon, R Marc Lebel, David C Alsop

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gopal VarmaDivision of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.ORCID 0000-0002-7060-1982
Fanny MunschDivision of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.ORCID 0000-0002-7144-8617
Brian BurnsGE Healthcare, Waukesha, Wisconsin, USA.
Guillaume DuhamelAix-Marseille Univ, CNRS, CRMBM, Marseille, France.ORCID 0000-0001-5704-8513
Olivier M GirardAix-Marseille Univ, CNRS, CRMBM, Marseille, France.ORCID 0000-0002-5296-638X
Arnaud GuidonGE Healthcare, Waukesha, Wisconsin, USA.ORCID 0000-0001-6777-1633
R Marc LebelGE Healthcare, Waukesha, Wisconsin, USA.ORCID 0000-0002-7526-9974
David C AlsopDivision of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.ORCID 0000-0002-8206-1995

Funding

Magnetic resonance imaging of human post-mortem tissues with a clinical diagnosis of multiple sclerosis using inhomogeneous magnetization transferR21NS114546 · NINDS · BETH ISRAEL DEACONESS MEDICAL CENTER · PI VARMA, GOPAL · 2019 to 2020
$481k
NINDS NIH HHS R21 NS114546
6 · The paper itself

Abstract

purposeTo demonstrate the feasibility of integrating the magnetization transfer (MT) preparations required for inhomogeneous MT (ihMT) within an MPRAGE-style acquisition. Such a sequence allows for reduced power deposition and easy inclusion of other modules.

methodsAn ihMT MPRAGE-style sequence (ihMTRAGE) was initially simulated to investigate acquisition of the 3D ihMT data sequentially, or in an interleaved manner. The ihMTRAGE sequence was implemented on a 3T clinical scanner to acquire ihMT data from the brain and spine.

resultsBoth simulations and in vivo data provided an ihMT signal that was significantly greater using a sequential ihMTRAGE acquisition, compared with an interleaved implementation. Comparison with a steady-state ihMT acquisition (defined as having one MT RF pulse between successive acquisition modules) demonstrated how ihMTRAGE allows for a reduction in average power deposition, or greater ihMT signal at equal average power deposition. Inclusion of a prospective motion-correction module did not significantly affect the ihMT signal obtained from regions of interest in the brain. The ihMTRAGE acquisition allowed combination with a spatial saturation module to reduce phase wrap artifacts in a cervical spinal cord acquisition.

conclusionsUse of preparations necessary for ihMT experiments within an MPRAGE-style sequence provides a useful alternative for acquiring 3D ihMT data. Compared with our steady-state implementation, ihMTRAGE provided reduced power deposition, while allowing use of the maximum intensity from off-resonance RF pulses. The 3D ihMTRAGE acquisition allowed combination of other modules with the preparation necessary for ihMT experiments, specifically motion compensation and spatial saturation modules.

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingArtifactsBrainImaging, Three-DimensionalProspective Studiesbraininhomogeneous magnetization transferMPRAGEMTmyelinspinal cord

Identifiers

PMID32602958
PMCPMC7722070

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.