Evidence map›Paper›PMID 32602335›Full record

ArticleACS sensors2020

Multiplex Digital MicroRNA Detection Using Cross-Inhibitory DNA Circuits.

Yannick Rondelez, Guillaume Gines

Abstract read
In one paragraph

Article in ACS sensors, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Coupling Exponential to Linear Amplification for Endpoint Quantitative Analysis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yannick RondelezGulliver Laboratory, ESPCI Paris-Université PSL, 10 rue Vauquelin, 75005 Paris, France.ORCID 0000-0002-2565-476X
Guillaume GinesGulliver Laboratory, ESPCI Paris-Université PSL, 10 rue Vauquelin, 75005 Paris, France.ORCID 0000-0003-1012-3250

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ubiquitous post-transcriptional regulators in eukaryotes, microRNAs are currently emerging as promising biomarkers of physiological and pathological processes. Multiplex and digital detection of microRNAs represents a major challenge toward the use of microRNA signatures in clinical settings. The classical reverse transcription polymerase chain reaction quantification approach has important limitations because of the need for thermocycling and a reverse transcription step. Simpler, isothermal alternatives have been proposed, yet none could be adapted in both a digital and multiplex format. This is either because of a lack of sensitivity that forbids single molecule detection or molecular cross-talk reactions that are responsible for nonspecific amplification. Building on an ultrasensitive isothermal amplification mechanism, we present a strategy to suppress cross-talk reactions, allowing for robust isothermal and multiplex detection of microRNA targets. Our approach relies on target-specific DNA circuits interconnected with DNA-encoded inhibitors that repress nonspecific signal amplification. We demonstrate the one-step, isothermal, digital, and simultaneous quantification of various pairs of important microRNA targets.

Indexed as

MicroRNAsDNADNAMicroRNAsdigital droplet detectionDNA circuitisothermal amplificationmicroRNAmultiplex assay

Identifiers

PMID32602335
PMCPMC7460561

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.