Evidence map›Paper›PMID 32602084›Full record

ArticleMolecular imaging and biology2020

Ultrafast Ultrasound Imaging for Super-Resolution Preclinical Cardiac PET.

Mailyn Perez-Liva, Thulaciga Yoganathan, Joaquin L Herraiz, Jonathan Porée, Mickael Tanter, Daniel Balvay, Thomas Viel, Anikitos Garofalakis, Jean Provost, Bertrand Tavitian

Open access · hybridAbstract read
In one paragraph

Article in Molecular imaging and biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 3 countries.

Mailyn Perez-LivaUniversité de Paris, PARCC, INSERM, 56, rue Leblanc, 75015, Paris, France. mailyn.perez-liva@inserm.fr.ORCID http://orcid.org/0000-0002-4985-247X
Thulaciga YoganathanUniversité de Paris, PARCC, INSERM, 56, rue Leblanc, 75015, Paris, France.
Joaquin L HerraizNuclear Physics Group and IPARCOS, Complutense University of Madrid, Plaza de las Ciencias, 1, 28020, Madrid, Spain.
Jonathan PoréePhysics for Medicine Paris, Inserm/ESPCI Paris-PSL/PSL-University/CNRS, 17 rue Moreau, 75012, Paris, France.
Mickael TanterPhysics for Medicine Paris, Inserm/ESPCI Paris-PSL/PSL-University/CNRS, 17 rue Moreau, 75012, Paris, France.
Daniel BalvayUniversité de Paris, PARCC, INSERM, 56, rue Leblanc, 75015, Paris, France.
Thomas VielUniversité de Paris, PARCC, INSERM, 56, rue Leblanc, 75015, Paris, France.
Anikitos GarofalakisUniversité de Paris, PARCC, INSERM, 56, rue Leblanc, 75015, Paris, France.
Jean ProvostEngineering physics department, Polytechnique Montréal, Montréal, Canada.
Bertrand TavitianUniversité de Paris, PARCC, INSERM, 56, rue Leblanc, 75015, Paris, France.
Inserm · FRCentre National de la Recherche Scientifique · FRMontreal Heart Institute · CAUniversidad Complutense de Madrid · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePhysiological motion and partial volume effect (PVE) significantly degrade the quality of cardiac positron emission tomography (PET) images in the fast-beating hearts of rodents. Several Super-resolution (SR) techniques using a priori anatomical information have been proposed to correct motion and PVE in PET images. Ultrasound is ideally suited to capture real-time high-resolution cine images of rodent hearts. Here, we evaluated an ultrasound-based SR method using simultaneously acquired and co-registered PET-CT-Ultrafast Ultrasound Imaging (UUI) of the beating heart in closed-chest rodents. PROCEDURES: The method was tested with numerical and animal data (n = 2) acquired with the non-invasive hybrid imaging system PETRUS that acquires simultaneously PET, CT, and UUI.

resultsWe showed that ultrasound-based SR drastically enhances the quality of PET images of the beating rodent heart. For the simulations, the deviations between expected and mean reconstructed values were 2 % after applying SR. For the experimental data, when using Ultrasound-based SR correction, contrast was improved by a factor of two, signal-to-noise ratio by 11 %, and spatial resolution by 56 % (~ 0.88 mm) with respect to static PET. As a consequence, the metabolic defect following an acute cardiac ischemia was delineated with much higher anatomical precision.

conclusionsOur results provided a proof-of-concept that image quality of cardiac PET in fast-beating rodent hearts can be significantly improved by ultrasound-based SR, a portable low-cost technique. Improved PET imaging of the rodent heart may allow new explorations of physiological and pathological situations related with cardiac metabolism.

Indexed as

Positron-Emission TomographyUltrasonographyAlgorithmsAnimalsCoronary VesselsFemaleHeartLigationNumerical Analysis, Computer-AssistedPhantoms, ImagingRats, WistarCardiac Positron Emission TomographyImage qualitySuper-resolutionUltrafast Ultrasound Imaging

Identifiers

PMID32602084
PMCPMC7497458
OpenAlexW3039122454

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.