Evidence map›Paper›PMID 32601994›Full record

ArticleMikrochimica acta2020

Core-satellite surface imprinting polymer-based pipette tip solid-phase extraction for the colorimetric determination of pyrethroid metabolite.

Tai Ye, An Liu, Long Bai, Min Yuan, Hui Cao, Jinsong Yu, Ran Yuan, Xiaozhe Xu, Hongen Yuan, Fei Xu

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 10 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Tai YeShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
An LiuShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Long BaiShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Min YuanShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Hui CaoShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Jinsong YuShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Ran YuanShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Xiaozhe XuShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Hongen YuanShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Fei XuShanghai Engineering Research Center for Food Rapid Detection, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China. xufei8135@126.com.ORCID 0000-0001-7745-2855
University of Shanghai for Science and Technology · CN

Funding

National Natural Science Foundation of China 31671934National Natural Science Foundation of China 31801636Science and Technology Commission of Shanghai Municipality 17391901500Science and Technology Commission of Shanghai Municipality 18YF1417300
6 · The paper itself

Abstract

A core-satellite-structured surface molecularly imprinted polymer has been synthesized for the enrichment of 3-phenoxybenzaldehyde by pipette tip solid-phase extraction (SPE). In a typical sol-gel process, two silane reagents as functional monomers and 3-phenoxybenzoic acid as the dummy template, the surface imprinting layer was coated on the core-satellite silica microsphere, which formed the core-satellite-structured molecularly imprinted polymer (CSMIP). Compared to the silica-based core-shell ones, this CS-MIP exhibits a stunning surface area (142 m

Indexed as

AdsorptionBenzaldehydesBenzoatesColorimetryDrinking WaterMolecular ImprintingMolecularly Imprinted PolymersPotassium PermanganateSolid Phase ExtractionWater Pollutants, Chemical3-phenoxybenzaldehyde3-phenoxybenzoic acidBenzaldehydesBenzoatesDrinking WaterMolecularly Imprinted PolymersPotassium PermanganateWater Pollutants, ChemicalCustomized deviceHierarchical structurePesticide

Identifiers

PMID32601994
OpenAlexW3037672030

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.