Evidence map›Paper›PMID 32601981›Full record

ArticleWorld journal of urology2021

Floating docking technique: a simple modification to improve the working space of the instruments during single-port robotic surgery.

Louis Lenfant, Soodong Kim, Alireza Aminsharifi, Guilherme Sawczyn, Jihad Kaouk

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in World journal of urology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. The First Single-Port Robotic-Assisted Excision of Choledochal Cyst and Hepaticojejunostomy in Children.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Louis LenfantDepartment of Glickman Urological and Kidney Institute, Center for Laparoscopic and Robotic Surgery, Institute Vice-Chair for Surgical Innovations, Cleveland Clinic, 9500 Euclid Ave, Q-10, Cleveland, OH, 44195, USA.ORCID http://orcid.org/0000-0001-9852-4002
Soodong KimDepartment of Glickman Urological and Kidney Institute, Center for Laparoscopic and Robotic Surgery, Institute Vice-Chair for Surgical Innovations, Cleveland Clinic, 9500 Euclid Ave, Q-10, Cleveland, OH, 44195, USA.
Alireza AminsharifiDepartment of Glickman Urological and Kidney Institute, Center for Laparoscopic and Robotic Surgery, Institute Vice-Chair for Surgical Innovations, Cleveland Clinic, 9500 Euclid Ave, Q-10, Cleveland, OH, 44195, USA.
Guilherme SawczynDepartment of Glickman Urological and Kidney Institute, Center for Laparoscopic and Robotic Surgery, Institute Vice-Chair for Surgical Innovations, Cleveland Clinic, 9500 Euclid Ave, Q-10, Cleveland, OH, 44195, USA.
Jihad KaoukDepartment of Glickman Urological and Kidney Institute, Center for Laparoscopic and Robotic Surgery, Institute Vice-Chair for Surgical Innovations, Cleveland Clinic, 9500 Euclid Ave, Q-10, Cleveland, OH, 44195, USA. kaoukj@ccf.org.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the range of motion and ergonomic characteristics of single-port robotic instruments in the setting of the "floating" versus "flat" docking technique using the GelPOINT MATERIAL AND

methodsThe basic principle of the floating docking technique resides in the GelSeal cap and trocar (s) being 8 cm off the skin level with the Alexis

resultsThe minimum required distances between the target and the tip of the cannula for activation of the wrist and elbow were 5 and 10 cm, respectively. When the target was near to the cannula (i.e., less than 10 cm), the floating technique was associated with a significant increase in the range of motion of the instrument in all directions. The working space volume of the instrument was increased by more than 390% (from 101 to 497 cm

Indexed as

Equipment DesignErgonomicsRobotic Surgical ProceduresDockingFloating techniqueGelportRobotic surgerySingle port surgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.