Evidence map›Paper›PMID 32601721›Full record

ArticleInternational orthopaedics2020

Neck modularity in total hip arthroplasty: a retrospective study of nine hundred twenty-eight titanium neck implants with a maximum follow-up of eighteen years.

Pietro Maniscalco, Fabrizio Quattrini, Corrado Ciatti, Laura Ghidoni, Giuseppe Ghidoni, Valeria Burgio, Francesco Pogliacomi, Enrico Vaienti, Francesco Ceccarelli

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Pseudotumor from ceramic-on-ceramic total hip arthroplasty.International journal of surgery case reports · 2024
    Article
  6. Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Article
  7. Article
  8. Article
  9. Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2023
    Article
  10. Comparison of single taper and dual taper versions of the same stem design in total hip arthroplasty for primary osteoarthritis.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2023
    Article
  11. Article
  12. Review
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Pietro ManiscalcoGuglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy.
Fabrizio QuattriniGuglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy.
Corrado CiattiGuglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy. dadociatti@icloud.com.ORCID http://orcid.org/0000-0002-7094-4344
Laura GhidoniGuglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy.
Giuseppe GhidoniGuglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy.
Valeria BurgioGuglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy.
Francesco PogliacomiMajor Hospital, Parma, Italy.
Enrico VaientiMajor Hospital, Parma, Italy.
Francesco CeccarelliMajor Hospital, Parma, Italy.
Guglielmo da Saliceto Hospital · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeNeck modularity was introduced to improve total hip arthroplasty (THA) accuracy, but it has been associated with early breakages and corrosion issues. In our hospital, modular necks have been in clinical use since the 1990s. We retrospectively analysed the occurrence of these sequelae in implants placed between January 2000 and December 2014.

methodsSurvival data from patients operated on in our hospital were obtained from the regional arthroplasty registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO). The cohort comprised 928 THAs on 908 patients. The average patient age was 67.8 years. Main indications were primary osteoarthritis (71.4%), fracture (9.2%), congenital dysplasia or congenital luxation (7.8%), and idiopathic osteonecrosis (6.4%). All femoral stems were cementless, with 318 anatomically shaped (34.3%), 579 straight (62.4%), and 31 short stems (3.3%). All necks used were made of titanium alloy. The average follow-up time was 9.6 years (range, 4-18 years).

resultsIn total, 66 revisions were reported. The main revision causes were periprosthetic fractures (33.3%), aseptic stem loosening (19.7%), luxation (18.2%), and implant breakage (12.1%). Five modular neck breakages were recorded. The overall survival rate was 87.7% at 17 years. We did not observe any component corrosion. The neck breakage rate was 0.5%, and the luxation rate was 1.3%.

conclusionsOur experience suggests that neck modularity is a safe, effective way to reconstruct the proximal femur in THA patients. We attribute the absence of corrosion to the exclusive use of titanium necks.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAgedFollow-Up StudiesHumansProsthesis DesignProsthesis FailureReoperationRetrospective StudiesTitaniumTitaniumCementless stemsNeck modularityPrimary total hip arthroplastySurvival analysisTitanium alloy necks

Identifiers

PMID32601721
OpenAlexW3038479401

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.