ArticleImaging science in dentistry2020

Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density.

Hugo Gaêta-Araujo, Eduarda Helena Leandro Nascimento, Danieli Moura Brasil, Daniela Verardi Madlum, Francisco Haiter-Neto, Christiano Oliveira-Santos

Open access · goldAbstract read
In one paragraph

Article in Imaging science in dentistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Hugo Gaêta-AraujoDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0001-5087-5022
Eduarda Helena Leandro NascimentoDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0002-9088-2320
Danieli Moura BrasilDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0002-9519-4578
Daniela Verardi MadlumDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0002-1364-6850
Francisco Haiter-NetoDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0002-5610-8307
Christiano Oliveira-SantosDepartment of Stomatology, Public Oral Health, Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0001-9936-7547
Universidade Estadual de Campinas (UNICAMP) · BRUniversidade de Ribeirão Preto · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. MATERIALS AND

methodsThe sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations (standard protocol; SP) for the application of artifact correction tools (beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett

resultsThe BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (

conclusionBMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD.

Indexed as

ArtifactsBone DensityX-Ray Microtomography