Evidence map›Paper›PMID 32601380›Full record

Observational studyScientific reports2020

Approximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation.

Long Shao, Xiang-Dong Wu, Ting Wang, Xiao-Kang Liu, Wei Xu, Wei Huang, Zhi-Min Zeng

Abstract readObservational Study
In one paragraph

Observational study in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. [Effect of tibial rotation on knee and ankle function in patients with extra-articular distal tibial fractures after minimally invasive plate osteosynthesis treatment].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Long Shao *Department of Orthopaedic Surgery, Ningbo No. 6 Hospital, 1059 Zhongshan East Road, Ningbo, Zhejiang, China.
Xiang-Dong Wu *Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Ting WangDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuan Jiagang, Yuzhong District, Chongqing, China.
Xiao-Kang LiuLab of Computer Vision, School of Electronics and Information Communications, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, China.
Wei XuDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuan Jiagang, Yuzhong District, Chongqing, China.
Wei HuangDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuan Jiagang, Yuzhong District, Chongqing, China. huangwei68@263.net.
Zhi-Min ZengDepartment of Orthopaedic Surgery, Ningbo No. 6 Hospital, 1059 Zhongshan East Road, Ningbo, Zhejiang, China. 923752576@qq.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traditionally, the practice of the tibial component placement in total knee arthroplasty has focused on achieving maximum coverage without malrotation. However, the concept of maximizing coverage has not been well defined or researched and yet biased results are often produced. This study aimed to evaluate the effect of a prioritizing maximum coverage positioning strategy on the rotational alignment by using a strict computer algorithm. Computed tomographic scans of 103 tibial specimens were used to reconstruct three-dimensional tibia models. A virtual surgery was performed to generate the resection plane with a posterior slope of 7° on the proximal tibia. Symmetrical and anatomical tibial components were placed and analyzed with an automated program designed for approximating the maximum coverage based on the coherent point drift algorithm. We found that the average tibial coverage achieved across all specimens and implants was 85.62 ± 3.65%, ranging from 83.64 ± 4.10% to 86.69 ± 3.07%. When placed for maximal tibial coverage, the mean degree of rotation related to the Insall line was - 0.73° ± 4.53° for all subjects, 23% of the tibial components were malrotated. The average percentage position of the baseplate anteroposterior axis over the patellar tendon was 26.95 ± 14.71% from the medial edge. These results suggest that with specific design and proper placement of the component, approximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation. The current tibial baseplates have shown good performance on the coverage when aligned parallel to the Insall line with the anteroposterior axis positioned between the medial 1/3 and medial 1/6 of the patella tendon.

Indexed as

Knee ProsthesisAdultAgedAlgorithmsArthroplasty, Replacement, KneeComputer SimulationFemaleHumansImaging, Three-DimensionalKnee JointMaleMiddle AgedModels, AnatomicTibiaYoung Adult

Identifiers

PMID32601380
PMCPMC7324544

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked