Evidence map›Paper›PMID 32599882›Full record

ArticleMicromachines2020

Pushing the Limits of Spatial Assay Resolution for Paper-Based Microfluidics Using Low-Cost and High-Throughput Pen Plotter Approach.

Reza Amin, Fariba Ghaderinezhad, Caleb Bridge, Mikail Temirel, Scott Jones, Panteha Toloueinia, Savas Tasoglu

Abstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Hemp-Based Microfluidics.Micromachines · 2021
    Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Reza AminDepartment of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA.
Fariba GhaderinezhadDepartment of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA.
Caleb BridgeDepartment of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA.
Mikail TemirelDepartment of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA.
Scott JonesDepartment of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA.
Panteha ToloueiniaInstitute of Materials Science (IMS), University of Connecticut, 97 North Eagleville Road, Storrs, CT 06269, USA.
Savas TasogluDepartment of Mechanical Engineering, Koç University, Sariyer, Istanbul 34450, Turkey.

Funding

American Heart Association 15SDG25080056Connecticut Innovations Biopipeline AwardUniversity of Connecticut Research Excellence Program Award
6 · The paper itself

Abstract

To transform from reactive to proactive healthcare, there is an increasing need for low-cost and portable assays to continuously perform health measurements. The paper-based analytical devices could be a potential fit for this need. To miniaturize the multiplex paper-based microfluidic analytical devices and minimize reagent use, a fabrication method with high resolution along with low fabrication cost should be developed. Here, we present an approach that uses a desktop pen plotter and a high-resolution technical pen for plotting high-resolution patterns to fabricate miniaturized paper-based microfluidic devices with hundreds of detection zones to conduct different assays. In order to create a functional multiplex paper-based analytical device, the hydrophobic solution is patterned on the cellulose paper and the reagents are deposited in the patterned detection zones using the technical pens. We demonstrated the effect of paper substrate thickness on the resolution of patterns by investigating the resolution of patterns on a chromatography paper with altered effective thickness. As the characteristics of the cellulose paper substrate such as thickness, resolution, and homogeneity of pore structure affect the obtained patterning resolution, we used regenerated cellulose paper to fabricate detection zones with a diameter as small as 0.8 mm. Moreover, in order to fabricate a miniaturized multiplex paper-based device, we optimized packing of the detection zones. We also showed the capability of the presented method for fabrication of 3D paper-based microfluidic devices with hundreds of detection zones for conducting colorimetric assays.

Indexed as

colorimetric analysishigh-resolutionmedical diagnosticsmicrofluidicsminiaturized paper-based assaymultiplex assays

Identifiers

PMID32599882
PMCPMC7344671

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.