Evidence map›Paper›PMID 32597094›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2020

[Design and performance analysis of elastic temporomandibular joint structure of biomimetic masticatory robot].

Wenlong Qin, Ming Cong, Xiang Ren, Haiying Wen, Dong Liu

Abstract read
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wenlong QinSchool of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, P.R.China.
Ming CongSchool of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, P.R.China.
Xiang RenCollege of Stomatology, Dalian Medical University, Dalian, Liaoning 116044, P.R.China.
Haiying WenSchool of Mechanical Engineering, Southeast University, Nanjing 211189, P.R.China.
Dong LiuSchool of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, P.R.China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Masticatory robots have a broad application prospect in the field of denture material tests and mandible rehabilitation. Mechanism type of temporomandibular joint structure is an important factor influencing the performance of the masticatory robot. In view of the wide application of elastic components in the field of the biomimetic robot, an elastic component was adopted to simulate the buffering characteristics of the temporomandibular joint disc and formed the elastic temporomandibular joint structure on the basis of point-contact high pair. Secondly, the influences of the elastic temporomandibular joint structure (on mechanism degree, kinematics, dynamics, etc.) were discussed. The position and velocity of the temporomandibular joint were analyzed based on geometric constraints of the joint surface, and the dynamic analysis based on the Lagrange equation was carried out. Finally, the influence of the preload and stiffness of the elastic component was analyzed by the response surface method. The results showed that the elastic temporomandibular joint structure could effectively guarantee the flexible movement and stable force of the joint. The elastic joint structure proposed in this paper further improves the biomimetic behavior of masticatory robots. It provides new ideas for the biomimetic design of viscoelastic joint discs.

Indexed as

BiomimeticsRoboticsTemporomandibular Joint DisordersHumansTemporomandibular JointTemporomandibular Joint Discelastic componentmasticatory robotmechanism designperformance analysistemporomandibular joint

Identifiers

PMID32597094
PMCPMC10319578

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.