Evidence map›Paper›PMID 32595140›Full record

ArticleOpen heart2020

Catheter strategy to ease the procedure and reduce radiation exposure when requiring neck access.

Rouven Kubicki, Johanna Hummel, René Höhn, Kevin Müller, Brigitte Stiller, Jochen Grohmann

Abstract read
In one paragraph

Article in Open heart, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Expanding the Reach of Pediatric Transcatheter Pacing.The Journal of innovations in cardiac rhythm management · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Rouven KubickiDepartment of Congenital Heart Disease and Paediatric Cardiology, University Heart Center Freiburg - Bad Krozingen, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany, Freiburg, Germany Rouven.kubicki@universitaets-herzzentrum.de.ORCID 0000-0002-9125-8626
Johanna HummelDepartment of Congenital Heart Disease and Paediatric Cardiology, University Heart Center Freiburg - Bad Krozingen, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany, Freiburg, Germany.
René HöhnDepartment of Congenital Heart Disease and Paediatric Cardiology, University Heart Center Freiburg - Bad Krozingen, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany, Freiburg, Germany.
Kevin MüllerDepartment of Occupational Safety, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany, Freiburg, Germany.
Brigitte StillerDepartment of Congenital Heart Disease and Paediatric Cardiology, University Heart Center Freiburg - Bad Krozingen, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany, Freiburg, Germany.
Jochen GrohmannDepartment of Congenital Heart Disease and Paediatric Cardiology, University Heart Center Freiburg - Bad Krozingen, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany, Freiburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess the potential occupational radiation reduction and technical feasibility in patients rotated 180° (upside-down) when requiring neck access for transcervical or trans-subclavian catheterisation.

methodsUpside-down positioning is defined as rotating patients in supine position by 180°, so that the feet come to rest where the head would otherwise be. We retrospectively evaluated all these procedures performed between March 2016 and May 2019. Furthermore, two different phantoms (paediatric and adult) were used prospectively to quantify the occupational dose between conventional or upside-down positioning. In this context, ambient dose equivalents were measured using real-time dosimeters. Three different projection angles were applied.

results44 patients with median age and body weight of 1.0 year (range 0-56) and 9.5 kg (range 1.3-74.3) underwent 63 procedures positioned upside-down. This position proved advantageous for practical reasons, since the length of the examination table could be optimally used. Additionally, it resulted in a significantly lower overall ambient dose equivalent for the primary operator (PO) of 94.8% (mean: 2569±807 vs 135±23 nSv; p<0.01) in the adult, and of 65.5% (mean: 351±104 vs 121±56 nSv; p<0.01) in the paediatric phantom, respectively.

conclusionUpside-down positioning facilitates handling in a straightforward manner when access from the neck is required. Moreover, it significantly reduces local radiation exposure for the PO in the paediatric and, most impressively, in the adult phantom.

Indexed as

Catheterization, Central VenousOccupational HealthPatient PositioningRadiography, InterventionalSupine PositionAdolescentAdultChildChild, PreschoolFeasibility StudiesFemaleHumansInfantInfant, NewbornMaleMiddle Agedcongenital heart diseaseimaging and diagnosticsinterventional cardiologypaediatric cardiac functionpaediatric interventional cardiology

Identifiers

PMID32595140
PMCPMC7322512

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.