Evidence map›Paper›PMID 32594196›Full record

SynthesisEuropean journal of nuclear medicine and molecular imaging2021

The value of

D Ten Hove, G Treglia, R H J A Slart, K Damman, M Wouthuyzen-Bakker, D F Postma, O Gheysens, R J H Borra, G Mecozzi, P P van Geel and 2 more

Open access · hybridAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in European journal of nuclear medicine and molecular imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 2 pooled it
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 2 syntheses or guidelines pooled it, 50 citations in OpenAlex.

  1. Pooled it
  2. EANM/SNMMI guideline/procedure standard for [European journal of nuclear medicine and molecular imaging · 2025
    Guideline
  3. Article
  4. Article
  5. Infections in mechanical circulatory support.Frontiers in cardiovascular medicine · 2026
    Review
  6. Article
  7. Infections in Patients with Mechanical Circulatory Support.Infectious disease clinics of North America · 2024
    Review
  8. Innovations in Imaging:Current cardiology reports · 2024
    Review
  9. Article
  10. Review
  11. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2024
    Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Recent biomedical advances enabled by HaloTag technology.Biocell : official journal of the Sociedades Latinoamericanas de Microscopia Electronica ... et. al · 2022
    Article
  17. Nuclear Imaging in Infective Endocarditis.Pharmaceuticals (Basel, Switzerland) · 2021
    Review
  18. Current cardiology reports · 2021
    Review
  19. Review
  20. Ventricular Assist Device-Specific Infections.Journal of clinical medicine · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 3 countries.

D Ten HoveDepartment of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713GZ, Groningen, The Netherlands. d.ten.hove@umcg.nl.ORCID 0000-0002-0717-6530
G TregliaClinic of Nuclear Medicine and PET/CT Centre, Imaging Institute of Southern Switzerland, Ente Ospedaliero Cantonale, Bellinzona and Lugano, Switzerland.
R H J A SlartDepartment of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713GZ, Groningen, The Netherlands.
K DammanUniversity of Groningen, Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
M Wouthuyzen-BakkerDepartment of Medical Microbiology and Infection Prevention, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
D F PostmaDepartment of Internal Medicine and infectious diseases, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
O GheysensDepartment of Nuclear Medicine, Cliniques Universitaires Saint-Luc, Brussels, Belgium.
R J H BorraDepartment of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713GZ, Groningen, The Netherlands.
G MecozziDepartment of Cardiothoracic Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
P P van GeelUniversity of Groningen, Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
B SinhaDepartment of Medical Microbiology and Infection Prevention, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
A W J M GlaudemansDepartment of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713GZ, Groningen, The Netherlands.
University Medical Center Groningen · NLCliniques Universitaires Saint-Luc · BEEnte Ospedaliero Cantonale · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLeft ventricular assist devices (LVADs) are increasingly used for the treatment of advanced heart failure. LVADs improve quality of life and decrease mortality, but the driveline carries substantial risk for major infections. These device-related LVAD and driveline infections are difficult to diagnose with conventional imaging. We reviewed and analysed the current literature on the additive value of MATERIALS/

methodsWe performed a systematic literature review using several databases from their inception until the 31st of December, 2019. Studies investigating the diagnostic performance of FDG-PET/CT in patients with suspected LVAD infection were retrieved. After a bias risk assessment using QUADAS-2, a study-aggregate meta-analysis was performed on a per examination-based analysis.

resultsA total of 10 studies were included in the systematic review, eight of which were also eligible for study-aggregate meta-analysis. For the meta-analysis, a total of 256 FDG-PET/CT scans, examining pump/pocket and/or driveline infection, were acquired in 230 patients. Pooled sensitivity of FDG-PET/CT was 0.95 (95% confidence interval (CI) 0.89-0.97) and pooled specificity was 0.91 (95% CI 0.54-0.99) for the diagnosis of device-related infection. For pump/pocket infection, sensitivity and specificity of FDG-PET/CT were 0.97 (95%CI 0.69-1.00) and 0.93 (95%CI 0.64-0.99), respectively. For driveline infection, sensitivity and specificity were 0.96 (95%CI 0.88-0.99) and 0.99 (95%CI 0.13-1.00) respectively. Significant heterogeneity existed across studies for specificity, mostly caused by differences in scan procedures. Predefined criteria for suspicion of LVAD and/or driveline infection were lacking in all included studies.

conclusionsFDG-PET/CT is a valuable tool for assessment of device-related infection in LVAD patients, with high sensitivity and high, albeit variable, specificity. Standardization of FDG-PET/CT procedures and criteria for suspected device-related LVAD infections are needed for consistent reporting of FDG-PET/CT scans.

Indexed as

Heart-Assist DevicesProsthesis-Related InfectionsFluorodeoxyglucose F18HumansPositron-Emission TomographyPositron Emission Tomography Computed TomographyQuality of LifeRadiopharmaceuticalsSensitivity and SpecificityFluorodeoxyglucose F18Radiopharmaceuticals18F-FDG PET/CTLVAD infectionMeta-analysisSystematic review

Identifiers

PMID32594196
PMCPMC7835315
OpenAlexW3037054470

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked