Evidence map›Paper›PMID 32592276›Full record

ArticleJournal of clinical laboratory analysis2020

Development of a sensitive HPLC-MS/MS method for 25-hydroxyvitamin D

XianTing Jiao, Yichun Yuan, Xirui Wang, Juan Li, Bin Liu, Tao Yuan, XiaoDan Yu

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Development of a sensitive HPLC-MS/MS method for 25-hydroxyvitamin DJournal of clinical laboratory analysis · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

XianTing JiaoDepartment of Developmental and Behavioral Pediatrics, Pediatric Translation Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Yichun YuanDepartment of Developmental and Behavioral Pediatrics, Pediatric Translation Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Xirui WangDepartment of Developmental and Behavioral Pediatrics, Pediatric Translation Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Juan LiDepartment of Developmental and Behavioral Pediatrics, Pediatric Translation Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Bin LiuCollege of Food Science, Fujian Agriculture and Forestry University, Fuzhou, China.
Tao YuanSchool of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
XiaoDan YuDepartment of Developmental and Behavioral Pediatrics, Pediatric Translation Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0003-2283-7138
Shanghai Jiao Tong University · CNFujian Agriculture and Forestry University · CN

Funding

Medical and Engineering Cooperation Project of Shanghai Jiao Tong University YG2017ZD15National Key Research Program of China 2016YFC1305204Shanghai Children's Health Services Capacity Program GDEK201708Shanghai Jiao Tong UniversityShanghai Pudong Health System Excellent Community Suitable Talent Cultivation Program PWRs2017-35the Chinese National Natural Science Number 81773411the Science and Technology Commission Project of Shanghai Pudong New Area PKJ2017-Y05
6 · The paper itself

Abstract

backgroundMeasurement of 25-hydroxyvitamin D [25(OH)D)] levels is important. The current method requires a relatively large volume of serum. To minimize the amount of serum needed, we established a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method to measure 25(OH)D in capillary serum.

methodsVenous blood and fingertip blood were collected from 90 participants. Volumes of 100 µL of venous serum and 20 µL of capillary serum were collected. The serum samples were pretreated by protein removal, extraction and concentration, and an HPLC-MS/MS method based on chromatographic separation and multi reactive ion monitoring was conducted. The intra- and inter-batch variation coefficients were less than 10% for both 25-hydroxyvitamin D

resultsThe limit of detection (LOD) of 25(OH)D

conclusionsThis capillary blood method requires minimal sample preparation and is suitable for routine use in the 25(OH)D detection.

Indexed as

25-Hydroxyvitamin D 2Blood Chemical AnalysisCalcifediolCapillariesChromatography, High Pressure LiquidHumansLimit of DetectionReproducibility of ResultsTandem Mass Spectrometry25-Hydroxyvitamin D 2Calcifediol25(OH)D25(OH)D3capillary bloodhigh-performance liquid chromatography-tandem mass spectrometry

Identifiers

PMID32592276
PMCPMC7595913
OpenAlexW3037006770

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.