Evidence map›Paper›PMID 32592068›Full record

ArticleInternational journal of computer assisted radiology and surgery2020

Automatic task recognition in a flexible endoscopy benchtop trainer with semi-supervised learning.

Valentin Bencteux, Guinther Saibro, Eran Shlomovitz, Pietro Mascagni, Silvana Perretta, Alexandre Hostettler, Jacques Marescaux, Toby Collins

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 7 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Valentin BencteuxIRCAD Strasbourg, Strasbourg, France. valentin.bencteux@ihu-strasbourg.eu.ORCID http://orcid.org/0000-0002-8243-4886
Guinther SaibroIRCAD Strasbourg, Strasbourg, France.
Eran ShlomovitzUHN Toronto, Toronto, Canada.
Pietro MascagniIRCAD Strasbourg, Strasbourg, France.
Silvana PerrettaIRCAD Strasbourg, Strasbourg, France.
Alexandre HostettlerIRCAD Strasbourg, Strasbourg, France.
Jacques MarescauxIRCAD Strasbourg, Strasbourg, France.
Toby CollinsIRCAD Strasbourg, Strasbourg, France.
Institut de Recherche contre les Cancers de l’Appareil Digestif · FRUniversity Health Network · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeInexpensive benchtop training systems offer significant advantages to meet the increasing demand of training surgeons and gastroenterologists in flexible endoscopy. Established scoring systems exist, based on task duration and mistake evaluation. However, they require trained human raters, which limits broad and low-cost adoption. There is an unmet and important need to automate rating with machine learning.

methodWe present a general and robust approach for recognizing training tasks from endoscopic training video, which consequently automates task duration computation. Our main technical novelty is to show the performance of state-of-the-art CNN-based approaches can be improved significantly with a novel semi-supervised learning approach, using both labelled and unlabelled videos. In the latter case, we assume only the task execution order is known a priori.

resultsTwo video datasets are presented: the first has 19 videos recorded in examination conditions, where the participants complete their tasks in predetermined order. The second has 17 h of videos recorded in self-assessment conditions, where participants complete one or more tasks in any order. For the first dataset, we obtain a mean task duration estimation error of 3.65 s, with a mean task duration of 159 s ([Formula: see text] relative error). For the second dataset, we obtain a mean task duration estimation error of 3.67 s. We reduce an average of 5.63% in error to 3.67% thanks to our semi-supervised learning approach.

conclusionThis work is the first significant step forward to automate rating of flexible endoscopy students using a low-cost benchtop trainer. Thanks to our semi-supervised learning approach, we can scale easily to much larger unlabelled training datasets. The approach can also be used for other phase recognition tasks.

Indexed as

EndoscopesMachine LearningPattern Recognition, AutomatedSupervised Machine LearningAlgorithmsDiagnosis, Computer-AssistedEndoscopyEquipment DesignGastroenterologyHumansInternship and ResidencyReproducibility of ResultsTask Performance and AnalysisVideo RecordingBenchtop simulatorEducationFlexible endoscopyPhase recognitionSemi-supervised learningSkill

Identifiers

PMID32592068
OpenAlexW3037811525

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.