Evidence map›Paper›PMID 32591940›Full record

ArticleSurgical endoscopy2021

Stray energy transfer in single-incision robotic surgery.

Krzysztof J Wikiel, Douglas M Overbey, Heather Carmichael, Brandon C Chapman, John T Moore, Carlton C Barnett, Teresa S Jones, Thomas N Robinson, Edward L Jones

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Trial
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Krzysztof J WikielDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA. Krzysztof.Wikiel@CUAnschutz.edu.ORCID http://orcid.org/0000-0002-7969-3043
Douglas M OverbeyDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
Heather CarmichaelDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
Brandon C ChapmanDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
John T MooreDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
Carlton C BarnettDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
Teresa S JonesDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
Thomas N RobinsonDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
Edward L JonesDepartment of Surgery, the University of Colorado School of Medicine & the Denver Veterans Affairs Medical Center, Aurora, CO, USA.
University of Colorado Denver · USDuke University · USUniversity of Colorado Anschutz Medical Campus · USUniversity of Tennessee at Chattanooga · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionStray energy transfer from surgical monopolar radiofrequency energy instruments can cause unintended thermal injuries during laparoscopic surgery. Single-incision laparoscopic surgery transfers more stray energy than traditional laparoscopic surgery. There is paucity of published data concerning stray energy during single-incision robotic surgery. The purpose of this study was to quantify stray energy transfer during traditional, multiport robotic surgery (TRS) compared to single-incision robotic surgery (SIRS).

methodsAn in vivo porcine model was used to simulate a multiport or single-incision robotic cholecystectomy (DaVinci Si, Intuitive Surgical, Sunnyvale, CA). A 5 s, open air activation of the monopolar scissors was done on 30 W and 60 W coag mode (ForceTriad, Covidien-Medtronic, Boulder, CO) and Swift Coag effect 3, max power 180 W (VIO 300D, ERBE USA, Marietta, GA). Temperature of the tissue (°C) adjacent to the tip of the assistant grasper or the camera was measured with a thermal camera (E95, FLIR Systems, Wilsonville, OR) to quantify stray energy transfer.

resultsStray energy transfer was greater in the SIRS setup compared to TRS setup at the assistant grasper (11.6 ± 3.3 °C vs. 8.4 ± 1.6 °C, p = 0.013). Reducing power from 60 to 30 W significantly reduced stray energy transfer in SIRS (15.3 ± 3.4 °C vs. 11.6 ± 3.3 °C, p = 0.023), but not significantly for TRS (9.4 ± 2.5 °C vs. 8.4 ± 1.6 °C, p = 0.278). The use of a constant voltage regulating generator also minimized stray energy transfer for both SIRS (0.7 ± 0.4 °C, p < 0.001) and TRS (0.7 ± 0.4 °C, p < 0.001).

conclusionsMore stray energy transfer occurs during single-incision robotic surgery than multiport robotic surgery. Utilizing a constant voltage regulating generator minimized stray energy transfer for both setups. These data can be used to guide robotic surgeons in their use of safe, surgical energy.

Indexed as

LaparoscopyRoboticsRobotic Surgical ProceduresSurgical WoundAnimalsEnergy TransferSwineEnergyMonopolarRobotRobotic surgerySingle-incision robotic surgeryStray energy

Identifiers

PMID32591940
OpenAlexW3037458012

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.