Evidence map›Paper›PMID 32588096›Full record

ArticleSkeletal radiology2020

Impact of stem design and cementation on postoperative femoral antetorsion in 227 patients with total hip arthroplasty (THA).

Tim Fischer, Christoph Stern, Benjamin Fritz, Patrick O Zingg, Christian W A Pfirrmann, Reto Sutter

Open access · hybridAbstract read
In one paragraph

Article in Skeletal radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Tim FischerDepartment of Radiology, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. tim.fischer@balgrist.ch.ORCID http://orcid.org/0000-0002-1807-9146
Christoph SternDepartment of Radiology, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Benjamin FritzDepartment of Radiology, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Patrick O ZinggDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Christian W A PfirrmannDepartment of Radiology, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Reto SutterDepartment of Radiology, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveIn total hip arthroplasty (THA), surgeons attempt to achieve a physiological antetorsion. However, postoperative antetorsion of the femoral stem is known to show large variabilities. The purpose of this study was to assess whether postoperative antetorsion is influenced by stem design or cementation. MATERIALS AND

methodsThis retrospective study included 227 patients with a hip prosthesis with five different stem designs (S1: short curved, S2 and S3: standard straight, S4: standard straight collared, S5: cemented straight), who had metal suppressed 1.5T-MRI of the hip between February 2015 and October 2019. Measurement of femoral antetorsion was done independently by two fellowship-trained radiologists on axial images by measuring the angle between the long axis of the femoral neck and the posterior condylar tangent of the knee. Measured angles in the different groups were compared using the t test for independent samples.

resultsThe cementless collared stem S4 showed the highest antetorsion with 18.1° (± 10.5°; range -10°-45°), which was significantly higher than the antetorsion of the collarless S3 with 13.3° (± 8.4°; - 4°-29°) and the cemented S5 with 12.7° (± 7.7°; - 3°-27°) with p = 0.012 and p = 0.007, respectively. S1 and S2 showed an antetorsion of 14.8° (± 10.0°; 1°-37°) and 14.1° (± 12.2°; - 20°-41°). The torsional variability of the cementless stems (S1-4) was significantly higher compared with that of the cemented S5 with a combined standard deviation of 10.5° and 7.7° (p = 0.019).

conclusionProsthesis design impacts the postoperative femoral antetorsion, with the cementless collared stem showing the highest antetorsion. Cemented stems demonstrated significantly lower variability, suggesting the lowest rate of inadvertent malrotation.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisCementationFemurHumansProsthesis DesignRetrospective StudiesCementationFemoral antetorsionHipProsthesis

Identifiers

PMID32588096
PMCPMC7652799
OpenAlexW3037889802

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.