ArticleAJNR. American journal of neuroradiology2020

High Spatiotemporal Resolution 4D Flow MRI of Intracranial Aneurysms at 7T in 10 Minutes.

L M Gottwald, J Töger, K Markenroth Bloch, E S Peper, B F Coolen, G J Strijkers, P van Ooij, A J Nederveen

Abstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025
    Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Comparison of 2D and 4D Flow MRI in Neonates Without General Anesthesia.Journal of magnetic resonance imaging : JMRI · 2023
    Article
  14. Article
  15. Article
  16. Article
  17. Quality Control for 4D Flow MR Imaging.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

L M GottwaldFrom the Departments of Radiology and Nuclear Medicine (L.M.G., E.S.P., P.v.O., A.J.N.) lukas.gottwald@outlook.com.ORCID 0000-0002-7394-821X
J TögerDepartment of Diagnostic Radiology (J.T.), Skane University Hospital, Lund, Sweden.ORCID 0000-0002-3365-7282
K Markenroth BlochLund University Bioimaging Center (K.M.B.), Lund University, Lund, Sweden.ORCID 0000-0002-3310-6667
E S PeperFrom the Departments of Radiology and Nuclear Medicine (L.M.G., E.S.P., P.v.O., A.J.N.).ORCID 0000-0001-6571-3341
B F CoolenBiomedical Engineering and Physics (B.F.C., G.J.S.), Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.ORCID 0000-0003-3946-653X
G J StrijkersBiomedical Engineering and Physics (B.F.C., G.J.S.), Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.ORCID 0000-0001-6700-5058
P van OoijFrom the Departments of Radiology and Nuclear Medicine (L.M.G., E.S.P., P.v.O., A.J.N.).ORCID 0000-0001-8755-0192
A J NederveenFrom the Departments of Radiology and Nuclear Medicine (L.M.G., E.S.P., P.v.O., A.J.N.).ORCID 0000-0002-5477-973X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposePatients with intracranial aneurysms may benefit from 4D flow MR imaging because the derived wall shear stress is considered a useful marker for risk assessment and growth of aneurysms. However, long scan times limit the clinical implementation of 4D flow MR imaging. Therefore, this study aimed to investigate whether highly accelerated, high resolution, 4D flow MR imaging at 7T provides reliable quantitative blood flow values in intracranial arteries and aneurysms. MATERIALS AND

methodsWe used pseudospiral Cartesian undersampling with compressed sensing reconstruction to achieve high spatiotemporal resolution (0.5 mm isotropic, ∼30 ms) in a scan time of 10 minutes. We analyzed the repeatability of accelerated 4D flow scans and compared flow rates, stroke volume, and the pulsatility index with 2D flow and conventional 4D flow MR imaging in a flow phantom and 15 healthy subjects. Additionally, accelerated 4D flow MR imaging with high spatiotemporal resolution was acquired in 5 patients with aneurysms to derive wall shear stress.

resultsFlow-rate bias compared with 2D flow was lower for accelerated than for conventional 4D flow MR imaging (0.31 ± 0.13,

conclusionsHighly accelerated high spatiotemporal resolution 4D flow MR imaging at 7T in intracranial arteries and aneurysms provides repeatable and accurate quantitative flow values. Flow rate accuracy is significantly increased compared with conventional 4D flow scans.

Indexed as

AdultCerebrovascular CirculationFemaleHealthy VolunteersHemodynamicsHumansIntracranial AneurysmMagnetic Resonance ImagingMaleMiddle AgedNeuroimagingPhantoms, Imaging

Identifiers

PMID32586964
PMCPMC7357648

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.