ArticlePolymers2020
Solid-Contact Potentiometric Sensors Based on Stimulus-Responsive Imprinted Polymers for Reversible Detection of Neutral Dopamine.
Article in Polymers, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 21 citations in OpenAlex.
- Small-Molecule Detection in Biological Fluids: The Emerging Role of Potentiometric Biosensors.International journal of molecular sciences · 2025Review
- On-Demand, Reversible, Ultrasensitive Polymer Membrane Based on Molecular Imprinting Polymer.ACS nano · 2023Article
- Molecularly Imprinted Polymer Modified with an MWCNT Nanocomposite for the Fabrication of a Barbital Solid-Contact Ion-Selective Electrode.ACS omega · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
Abstract
Herein, we present for the first time a novel potentiometric sensor based on the stimulus-responsive molecularly imprinted polymer (MIP) as a selective receptor for neutral dopamine determination. This smart receptor can change its capabilities to recognize according to external environmental stimuli. Therefore, MIP-binding sites can be regenerated in the polymeric membrane by stimulating with stimulus after each measurement. Based on this effect, reversible detection of the analyte via potentiometric transduction can be achieved. MIPs based on 4-vinylphenylboronic acid as the functional monomer were prepared as the selective receptor. This monomer can successfully bind to dopamine via covalent binding and forming a five- or six-membered cyclic ester in a weakly alkaline aqueous solution. In acidic medium, the produced ester dissociates and regenerates new binding sites in the polymeric membrane. The proposed smart sensor exhibited fast response and good sensitivity towards dopamine with a limit of detection 0.15 µM over the linear range 0.2-10 µM. The selectivity pattern of the proposed ISEs was also evaluated and revealed an enhanced selectivity towards dopamine over several phenolic compounds. Constant-current chronopotentiometry is used for evaluating the short-term potential stability of the proposed ISEs. The obtained results confirm that the stimulus-responsive MIPs provide an attractive way towards reversible MIP-based electrochemical sensors designation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.