Electrode Humidification Design for Artifact Reduction in Capacitive ECG Measurements.

Yue Tang, Ronghui Chang, Limin Zhang, Feng Yan, Haowen Ma, Xiaofeng Bu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Special Issue: ECG Monitoring System.Sensors (Basel, Switzerland) · 2021
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Yue TangSchool of Electronic Science and Engineering, Nanjing University, Nanjing 210046, China.
Ronghui ChangSchool of Electronic Science and Engineering, Nanjing University, Nanjing 210046, China.
Limin ZhangSchool of Electronic Science and Engineering, Nanjing University, Nanjing 210046, China.ORCID 0000-0003-0933-8609
Feng YanSchool of Electronic Science and Engineering, Nanjing University, Nanjing 210046, China.
Haowen MaSchool of Electronic Science and Engineering, Nanjing University, Nanjing 210046, China.
Xiaofeng BuSchool of Electronic Science and Engineering, Nanjing University, Nanjing 210046, China.
Nanjing University · CN

Funding

National Key R&D Program of China 2016YFA0202102National Nature Science Foundation Program of China 91850204 and 11304152
6 · The paper itself

Abstract

For wearable capacitive electrocardiogram (ECG) acquisition, capacitive electrodes may cause severe motion artifacts due to the relatively large friction between the electrodes and the dielectrics. In some studies, water can effectively suppress motion artifacts, but these studies lack a complete analysis of how water can suppress motion artifacts. In this paper, the effect of water on charge decay of textile electrode is studied systematically, and an electrode controllable humidification design using ultrasonic atomization is proposed to suppress motion artifacts. Compared with the existing electrode humidification designs, the proposed electrode humidification design can be controlled by a program to suppress motion artifacts at different ambient humidity, and can be highly integrated for wearable application. Firstly, the charge decay mode of the textile electrode is given and it is found that the process of free water evaporation at an appropriate free water content can be the dominant way of triboelectric charge dissipation. Secondly, theoretical analysis and experiment verification both illustrate that water contained in electrodes can accelerate the decay of triboelectric charge through the free water evaporation path. Finally, a capacitive electrode controllable humidification design is proposed by applying integrated ultrasonic atomization to generate atomized drops and spray them onto textile electrodes to accelerate the decay of triboelectric charge and suppress motion artifacts. The performance of the proposed design is verified by the experiment results, which shows that the proposed design can effectively suppress motion artifacts and maintain the stability of signal quality at both low and high ambient humidity. The signal-to-noise ratio of the proposed design is 33.32 dB higher than that of the non-humidified design at 25% relative humidity and is 22.67 dB higher than that of non-humidified electrodes at 65% relative humidity.

Indexed as

ArtifactsElectrocardiographySignal Processing, Computer-AssistedElectrodesMotioncapacitive ECGhumidification designmotion artifacttextile electrodetriboelectric charge

Identifiers

PMID32570924
PMCPMC7349487
OpenAlexW3036371582

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.