Hydrodynamic Noise of Pulsating Jets through Bileaflet Mechanical Mitral Valve.
Article in BioMed research international, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 4 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Experimental research results of hydrodynamic noise of pulsating flow through a bileaflet mechanical mitral valve are presented. The pulsating flow of pure water corresponds to the diastolic mode of the cardiac rhythm heart. The valve was located between the model of the left atrium and the model of the left ventricle of the heart. A coordinate device, on which a block of miniature sensors of absolute pressure and pressure fluctuations was installed, was located inside the model of the left ventricle. It is found that the hydrodynamic noise of the pulsating side jet of the semiclosed valve is higher than for the open valve. The pressure fluctuation levels gradually decrease with the removal from the mitral valve. It is established that at the second harmonic of the pulsating flow frequency, the spectral levels of the hydrodynamic noise of the semiclosed bileaflet mechanical mitral valve are almost 5 times higher than the open valve. With the removal from the mitral valve, spectral levels of hydrodynamic noise are decreased, especially strongly at the frequency of the pulsating water flow and its higher harmonics.