Evidence map›Paper›PMID 32566381›Full record

ArticleInternational journal of sports physical therapy2020

THE TENSILE BEHAVIORS OF THE ILIOTIBIAL BAND - A CADAVERIC INVESTIGATION.

Gesine H Seeber, Mark P Wilhelm, Phillip S Sizer, Amini Guthikonda, Anja Matthijs, Omer C Matthijs, Djordje Lazovic, Jean-Michel Brismée, Kerry K Gilbert

Open access · diamondAbstract read
In one paragraph

Article in International journal of sports physical therapy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Gesine H Seeber
Mark P WilhelmTufts University School of Medicine, Medford, MA, USA.
Phillip S SizerCenter for Rehabilitation Research, Texas Tech University Health Sciences Center, Lubbock, TX, USA.
Amini GuthikondaDepartment of Kinesiology and Sports Management, Texas Tech University, Lubbock, TX, USA.
Anja Matthijs
Omer C Matthijs
Djordje LazovicUniversity Hospital for Orthopaedics and Trauma Surgery Pius-Hospital, Medical Campus University of Oldenburg, Oldenburg, Germany.
Jean-Michel BrisméeCenter for Rehabilitation Research, Texas Tech University Health Sciences Center, Lubbock, TX, USA.
Kerry K GilbertCenter for Rehabilitation Research, Texas Tech University Health Sciences Center, Lubbock, TX, USA.
Texas Tech University · USBöhler Edelstahl (Austria) · ATTexas Tech University Health Sciences Center · USTufts University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundClinical stretching is frequently recommended for iliotibial band syndrome management. Current literature lacks conclusive findings regarding isolated human iliotibial band tissue elongation and stiffness behaviors. Applying clinical-grade stretching force results to iliotibial band tissue behavior is thus challenging. PURPOSE: This study's objectives were to determine isolated iliotibial band tissue tensile behaviors during tension-to-failure testing and to relate the results to previously reported iliotibial band stretch findings. STUDY

designDescriptive in vitro laboratory study.

methodsTen isolated un-embalmed iliotibial band specimens were exposed to tension-to-failure testing using a 10kN material testing system. Peak load, load at yield point, and ultimate failure load were measured in Newtons. Corresponding absolute (mm) and relative (%) tissue deformation was recorded. Load-deformation curves were established to calculate iliotibial band stiffness (N/mm).

resultsA mean peak load of 872.8 ± 285.9N and resulting 9.0 ± 3.9% tissue deformation from initial length was recorded. An 805.5 ± 249.7N mean load at yield point and resulting 7.0 ± 1.9% tissue deformation was observed. A 727.6 ± 258.4N mean load was recorded directly prior to ultimate tissue failure. Mean tissue deformation at ultimate failure was 11.3 ± 4.2%. Mean iliotibial band system stiffness was 27.2 ± 4.5N/mm.

conclusionThe iliotibial band can withstand substantial tensile forces. Clinical stretching forces likely fall within the load-deformation curve elastic region and may not result in permanent iliotibial band tissue deformation. Sustained elongation resulting from stretching the ITB may require substantial patient compliance. Future studies should investigate potential underlying factors related to positive symptom relief from iliotibial band stretching that include immunological responses, fluid accumulation, altered proprioception, and pain perception. LEVEL OF EVIDENCE: 3.

Indexed as

Iliotibial bandload-to-failure testingstiffnesstensile behaviors

Identifiers

PMID32566381
PMCPMC7296993
OpenAlexW3036582396

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.