Evidence map›Paper›PMID 32566295›Full record

ArticleInternational journal of nephrology2020

A Simple Tenckhoff Catheter Placement Technique for Continuous Ambulatory Peritoneal Dialysis (CAPD) Using the Bandung Method.

Jonny, Rudi Supriyadi, Rully Roesli, Goh Bak Leong, Lydia Permata Hilman, Fidelisa Cita Arini

Open access · goldAbstract read
In one paragraph

Article in International journal of nephrology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

JonnyDivision of Nephrology, Internal Medicine Department, Gatot Soebroto Army Central Hospital, Jakarta, Indonesia.ORCID https://orcid.org/0000-0002-8564-7430
Rudi SupriyadiDivision of Nephrology, Internal Medicine Department, Faculty of Medicine, Padjadjaran University/Hasan Sadikin General Hospital, Bandung, Indonesia.
Rully RoesliDivision of Nephrology, Internal Medicine Department, Faculty of Medicine, Padjadjaran University/Hasan Sadikin General Hospital, Bandung, Indonesia.
Goh Bak LeongDivision of Nephrology, Serdang Hospital, Kajang, Selangor, Malaysia.ORCID https://orcid.org/0000-0002-4644-7743
Lydia Permata HilmanDivision of Nephrology, Internal Medicine Department, Gatot Soebroto Army Central Hospital, Jakarta, Indonesia.
Fidelisa Cita AriniDivision of Nephrology, Internal Medicine Department, Gatot Soebroto Army Central Hospital, Jakarta, Indonesia.
Gatot Soebroto Army Hospital · IDDr. Hasan Sadikin General Hospital · IDSerdang Hospital · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Insertion of Tenckhoff catheters for continuous ambulatory peritoneal dialysis by nephrologists remains uncommon in most developing countries, including Indonesia. The aim of this study is to describe our experience on a simple technique of Tenckhoff catheter insertion by a nephrologist called the Bandung method. We conducted a retrospective observational study from May 2012 until December 2018 in 230 patients with end-stage renal disease using the Bandung method, a blind percutaneous insertion approach modified from the Seldinger technique. Early complications after insertion were assessed. The mean age of patients was 47.28 years (range 14-84 years). Within 1 month after insertion, complications occurred in 34 patients: 13 (5.7%) malposition, 8 (3.5%) omental trapping, 6 (2.6%) outlow failure, 3 (1.3%) peritonitis, 1 (0.4%) catheter infections, 1 (0.4%) bleeding, 1 (0.4%) kinking, and 1 (0.4%) hernia. None of these complications led to catheter removal. One patient experienced a late (>1 month) post-insertion complication of malposition that could not be repositioned and led to catheter removal. The Bandung method is a simple, cost effective, and minimally invasive technique for Tenckhoff catheter insertion that is associated with the same rate of complications compared to other techniques. This technique may useful for application in developing countries.

Identifiers

PMID32566295
PMCPMC7284935
OpenAlexW3033768421

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.