Observational studyPloS one2020
Noninvasive investigation of the cardiodynamic response to 6MWT in people after stroke using impedance cardiography.
Observational study in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 8 citations in OpenAlex.
- Prognostic Value of Transthoracic Impedance Cardiography, Amino-Terminal Pro-B-Type Natriuretic Peptide Levels, The Six-Minute Walk Test, and Chest X-Ray in Elderly Patients with Chronic Heart Failure: A Comparative Study in Lithuania.Medical science monitor : international medical journal of experimental and clinical research · 2024Article
- Inertial Measurement Unit and Heart Rate Monitoring to Assess Cardiovascular Fitness of Manual Wheelchair Users during the Six-Minute Push Test.Sensors (Basel, Switzerland) · 2024Article
- Non-Invasive Assessment of Cardiodynamics by Impedance Cardiography during the Six-Minute Walk Test in Patients with Heart Failure.Arquivos brasileiros de cardiologia · 2023Observational
- Intrapulmonary distribution of blood flow during exercise in pulmonary hypertension assessed by a new combination technique.Frontiers in cardiovascular medicine · 2023Article
- Single-Center Study in Lithuania to Evaluate the Role of Transthoracic Impedance Cardiography in the Diagnosis and Outcome Evaluation of 301 Patients with Chronic Heart Failure Exacerbation.Medical science monitor : international medical journal of experimental and clinical research · 2022Article
- Stroke volume and cardiac output during 6 minute-walk tests are strong predictors of maximal oxygen uptake in people after stroke.PloS one · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This is a cross-section observational study that investigated the cardiodynamic response to a 6-minute walk test (6MWT) in patients after stroke using impedance cardiography (ICG). Patients diagnosed with stroke were invited to participate in a 6MWT on consecutive days. Heart rate (HR), cardiac output (CO), stroke volume (SV) and cardiac index (CI) were measured by ICG using the PhysioFlow® PF07 EnduroTM at 1-second intervals for 10 minutes prior to, during and for 10 minutes after each 6MWT. Oxygen saturation, perceived exertion score (modified Borg scale) and the distance covered at the end of each 6MWT were recorded. Twenty-nine patients (mean age 55.6±10.9 years) completed the study. The mean duration of stroke after diagnosis was 14.4±19.1 months. There were no differences in the measured data between the first and second 6MWT (mean intraclass correlation coefficient (ICC) range: 0.87-0.95). The 6 minute walk distance (6WMD) covered in the two 6MWTs was 246±126 and 255±130m respectively (p>0.05). Mean measured data for each subject at rest, and at the end of the better performed 6MWT were, respectively: HR 78±11 and 100±18 bpm; CO 5.5±1.2 and 8.9±2.6 l/min, SV 71.3±16 and 89.3±18.6 ml/beat and CI 3.0±0.6 and 4.9±1.3 l/min/m2. After commencement of the 6MWT, the increase in SV took 30 sec before the rise approaching a plateau, whereas HR, CO and CI continued to rise steeply for 90 sec before leveling off to a steady rise. After completion of the 6MWT, all parameters had returned to baseline by a mean of 3.5 min. Sub-group analysis showed that the increase in cardiac output was predominantly contributed by an increase in heart rate in participants diagnosed with stroke for less than 1 year, whereas both stroke volume and heart rate contributed similarly to the increase in cardiac output in participants with diagnosis of stroke for longer than 1 year. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) both returned to baseline within 2 minutes post 6MWT. HR recorded at the end of the 6MWT was 60.8±10.6% of the predicted maximal heart rate and perceived exertion score was 5±2. Correlations between 6MWD and HR, and between 6MWD and SV were weak, with correlation coefficients Spearman's rho (rs) =0.46, and 0.42, respectively (p<0.05). Correlation between 6MWD and CO and CI were higher (rs= 0.66 and 0.63, respectively (p<0.01)). This is the first study to report cardiac responses during a 6MWT in stroke patients. ICG is a reliable, non-invasive, repeatable method of measuring cardiodynamic data in stroke patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.