ArticleRO-MAN ... : the ... IEEE International Symposium on Robot and Human Interactive Communication : proceedings. IEEE International Symposium on Robot and Human Interactive Communication2019
Towards securing the sclera against patient involuntary head movement in robotic retinal surgery.
Article in RO-MAN ... : the ... IEEE International Symposium on Robot and Human Interactive Communication : proceedings. IEEE International Symposium on Robot and Human Interactive Communication, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- A novel 3D-printed noninvasive immobilizer for head stability during surgery of the orbit and skull base.3D printing in medicine · 2026Article
- A Shared Control Approach to Robot-Assisted Cataract Surgery Training for Novice Surgeons.Sensors (Basel, Switzerland) · 2025Article
- Spotlight-based 3D Instrument Guidance for Autonomous Task in Robot-assisted Retinal Surgery.IEEE robotics and automation letters · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
Abstract
Retinal surgery involves manipulating very delicate tissues within the confined area of eyeball. In such demanding practices, patient involuntary head movement might abruptly raise tool-to-eyeball interaction forces which would be detrimental to eye. This study is aimed at implementing different force control strategies and evaluating how they contribute to attaining sclera force safety while patient head drift is present. To simulate patient head movement, a piezoelectric-actuated linear stage is used to produce random motions in a single direction in random time intervals. Having an eye phantom attached to the linear stage then an experienced eye surgeon is asked to manipulate the eye and repeat a mock surgical task both with and without the assist of the Steady-Hand Eye Robot. For the freehand case, warning sounds were provided to the surgeon as auditory feedback to alert him about excessive slclra forces. For the robot-assisted experiments two variants of an adaptive sclera force control and a virtual fixture method were deployed to see how they can maintain eye safety under head drift circumstances. The results indicate that the developed robot control strategies are able to compensate for head drift and keep the sclera forces under safe levels as well as the free hand operation.
Identifiers
What OpenQuestion holds
Registered trials